VIOX V50L-32G Safety Breaker RCBO

VIOX V50L-32G RCBO offers comprehensive protection for AC 50Hz applications up to 240V and 32A. This IEC/EN 60898 compliant device features a 2500A breaking capacity and provides dual-pole protection against overloads, short circuits, and leakage currents. Available in 16A, 20A, 25A, and 32A ratings with C and D tripping curves, it’s ideal for modern household appliances and single-phase industrial circuits. Key advantages include compact design, zero line and fire line protection, and reliable operation even with reversed wiring. Operating from -5°C to +40°C and suitable for altitudes up to 2000m, this versatile RCBO ensures safety in various environments. Its infrequent operation capability and simultaneous pole disconnection make it a truly reliable choice for both residential and light industrial applications.

Шаардлагаа илгээнэ үү, бид танд 12 цагийн дотор үнийн санал өгөх болно

VIOX V50L-32G аюулгүйн таслуур Хэт гүйдлийн хамгаалалттай үлдэгдэл гүйдлийн таслуур

Тойм

The VIOX V50L-32G RCBO series is designed for AC 50Hz applications with rated voltage up to 240V and rated current up to 32A. These devices offer comprehensive protection against overload and short circuit for various modern household appliances, while also providing functionality for infrequent operation and control.

Гол онцлогууд

  • Өндөр таслах чадвар
  • Zero line and fire line intermittent protection
  • Leakage protection even in case of fire line reversal
  • Compact size with double pole structure design
  • Simultaneous connection and disconnection of both poles
  • Truly safe and reliable for civilian and industrial single-phase applications
  • Suitable for infrequent operation and control

Техникийн үзүүлэлтүүд

  • Standard: IEC/EN 60898
  • Type: RCBO V50L-32G
  • Protection: Overload and Short Circuit
  • Rated current: 16A, 20A, 25A, 32A
  • Characteristic: C curve (32A), D curve (16A, 20A, 25A)
  • Poles: 2 poles
  • Breaking capacity: 2500A
  • Rated voltage: 110VAC, 230VAC
  • Ambient Temperature: -5°C to +40°C (24-hour average not exceeding 35°C)
  • Altitude: 2,000m or less
  • Installation class: III
  • Pollution levels: II
Over-Load
Test No. Муруй төрөл Ачааллын гүйдэл Анхны төлөв Time Limit To Trip Estimated Result
1 C,D 1.13 инч хүйтэн байдал t≤1цаг Not trip
2 C,D 1.45 инч conntinuing the test t < 1 аялал
3 C,D 2.55 инч хүйтэн байдал 1s < t < 60s аялал
Богино холболт
Test No. Муруй төрөл Ачааллын гүйдэл Анхны төлөв Time Limit To Trip Estimated Result
4 C 5In хүйтэн байдал t≤0.1с Not trip
Д 10 инч
5 C 10 инч хүйтэн байдал t < 0.1s аялал
Д 20In
Ambiment temperature Rated current(A) -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C
16 19.20 18.40 17.76 16.96 16.00 15.36 14.88 14.24
20 24.00 23.00 22.20 21.20 20.00 19.20 18.60 17.80
25 30.00 28.75 27.75 26.50 25.00 24.00 23.25 22.25
32 38.72 37.12 35.52 33.92 32.00 30.72 29.76 28.16

Суурилуулалтын шаардлага

  • The magnetic field near the installation site should not be more than five times the magnetic field in any direction

Хэрэглээ

  • Protection of modern household appliances
  • Civilian and industrial single-phase circuits
  • Infrequent operation and control scenarios

Аюулгүй байдлын онцлогууд

  • Dual pole protection
  • Leakage protection in various wiring scenarios
  • Simultaneous pole operation for enhanced safety

Онцлог муруй

Холболтын диаграм

Хэмжээ

Холбоотой бүтээгдэхүүн

Одоо үнийн санал асуугаарай

Одоо үнийн санал асуугаарай