VOB4-125 MCB – High Current 6kA Miniature Circuit Breaker

  • High Current Ratings: 80A, 100A, 125A – ideal for main distribution and heavy loads
  • Enhanced Electrical Durability: 6,000 electrical cycles (50% more than standard 4,000 cycles)
  • Superior Endurance: ≥20,000 cycles for long-term reliability
  • Robust Breaking Capacity: 6000A short-circuit protection
  • Широкий діапазон напруги: 230V/400V~, 240V/415V~ for international applications
  • All Pole Configurations: 1P, 2P, 3P, 4P available
  • Type C & D Curves: Suitable for motors, transformers, and high-inrush loads
  • Professional Quality: Manufactured by ISO 9001:2015 certified VIOX Electric

Надішліть свої вимоги, і ми надамо вам пропозицію протягом 12 годин

VOB4-125 High-Current Miniature Circuit Breaker

Professional MCB for 80A-125A Heavy-Load Applications – VIOX VOB4-125 series miniature circuit breakers provide reliable high-current protection for main distribution boards, commercial buildings, and heavy-load installations. IEC 60898-1 certified with 6kA breaking capacity, enhanced 6000 electrical cycles durability, rated from 80A to 125A.

Complete Technical Specifications

Параметр Специфікація
Product Series VOB4-125
Номінальний струм (В) 80A, 100A, 125A
Кількість поляків 1P, 2P, 3P, 4P
Розривна здатність (Icn) 6000A
Номінальна напруга 230V/400V~, 240V/415V~
Trip Unit Technology Термомагнітний
Curve Code (Trip Characteristics) C, D
Номінальна імпульсна витримувана напруга (Uimp) 4000V
Механічна міцність 10 000 циклів
Електрична довговічність 6,000 cycles (enhanced)
Endurance ≥20,000 cycles
Момент затягування M7 3.5N·m ⚠
Ступінь захисту IP20
Діапазон температур навколишнього середовища -5°C to +40°C
Відповідність стандартам IEC 60898-1
Монтаж 35mm DIN rail (IEC/EN 60715)

VOB4-125 Key Advantages

1. High Current Capacity for Heavy Loads

The VOB4-125 series is specifically designed for high-current applications from 80A to 125A, making it perfect for:

  • Main distribution boards in commercial buildings
  • Heavy-load circuits in industrial facilities
  • Large motor and transformer protection
  • High-power HVAC systems
  • Промислове кухонне обладнання
  • Розподіл живлення центру обробки даних

2. Enhanced Electrical Durability – 6,000 Cycles

Unlike standard MCBs with 4,000 electrical cycles, the VOB4-125 offers 6,000 electrical cycles – a 50% increase in durability. This means:

  • Longer service life in demanding applications
  • Reduced maintenance and replacement costs
  • Better performance in circuits with frequent load switching
  • Higher reliability for critical installations

3. Superior Endurance Rating

With an endurance rating of ≥20,000 cycles, the VOB4-125 is built for the long term, providing:

  • Extended operational lifespan
  • Consistent performance over years of service
  • Cost-effective solution for high-usage environments

4. Versatile Voltage Compatibility

Supporting both 230V/400V~ and 240V/415V~ voltage systems, the VOB4-125 is suitable for:

  • International projects with different voltage standards
  • Both European and Asian electrical systems
  • Multi-voltage installations

Trip Curve Selection Guide

The VOB4-125 is available in Type C and Type D curves to match your specific application:

Type C Curve MCB (5-10 × In) – Recommended

Best for general commercial and light industrial applications:

  • Main distribution boards with mixed loads
  • Large air conditioning systems and HVAC equipment
  • Розподіл електроенергії в комерційних будівлях
  • Transformers and inductive loads
  • Motor-driven equipment (pumps, fans, compressors)
  • General power panels with moderate inrush currents

Trip Range: 5-10 times rated current
Типові застосування: Most commercial buildings, offices, retail spaces

Type D Curve MCB (10-20 × In)

Best for heavy industrial applications with high inrush currents:

  • Large industrial motors and motor starters
  • Heavy transformers with high magnetizing inrush
  • Welding equipment and industrial machinery
  • X-ray and medical imaging equipment
  • Capacitive loads with high starting currents
  • Industrial manufacturing equipment

Trip Range: 10-20 times rated current
Типові застосування: Industrial plants, heavy machinery, specialized equipment


Applications by Market Segment

Commercial Buildings & Offices

  • Main Distribution Boards: 80A-125A feeders for sub-distribution
  • Системи опалення, вентиляції та кондиціонування: Large rooftop units, chillers, central air conditioning
  • Elevator & Escalator Systems: Main power protection
  • Commercial Kitchen Equipment: Industrial ovens, refrigeration systems
  • Retail Stores: Main incoming protection for large retail spaces
  • Shopping Malls: Sub-main distribution circuits

Житлові програми

  • High-Load Residential Buildings: Main incoming protection for large homes
  • Multi-Unit Dwellings: Distribution boards for apartment buildings
  • Luxury Homes: High-power circuits for pools, spas, home theaters
  • Захист усього будинку: Main breaker for high-load residences
  • Зарядка для електромобілів: High-current EV charging installations

Промислові об'єкти

  • Центри управління двигунами: Protection for large industrial motors
  • Manufacturing Plants: Main distribution for production lines
  • Factory Power Distribution: Sub-main circuits in industrial facilities
  • Важке машинобудування: Protection for high-power industrial equipment
  • Технологічне обладнання: Промислова автоматизація та системи управління

Infrastructure & Utilities

  • Public Buildings: Schools, hospitals, government facilities
  • Transportation Hubs: Airports, train stations, bus terminals
  • Telecom & Data Centers: High-current power distribution
  • Water Treatment Plants: Pump and motor protection
  • Municipal Buildings: Main distribution protection

Спеціалізовані програми

  • Сонячні фотоелектричні системи: Main DC/AC protection circuits
  • Зберігання енергії акумулятора: High-current storage system protection
  • Системи аварійного живлення: Generator and UPS distribution
  • Medical Facilities: Critical power distribution circuits
  • Hospitality: Hotels, resorts, conference centers

VOB4-125 vs Lower-Rated MCBs

Особливість VOB4-63 (1A-63A) VOB4-125 (80A-125A)
Поточний діапазон 1A-63A 80A-125A
Електрична довговічність 4,000 cycles 6,000 cycles
Endurance Не вказано ≥20,000 cycles
Момент затягування M5 2.5N·m M7 3.5N·m (larger terminals)
Пропускна здатність 6kA/10kA 6 кА
Основне використання Відгалуження ланцюгів Main & Sub-Main Distribution
Typical Installation Final circuits Distribution boards, feeders

Choose VOB4-125 when:

  • Main distribution board protection is required (80A-125A)
  • High electrical durability (6,000 cycles) is needed
  • Heavy-load applications demand robust protection
  • Long-term reliability (20,000+ cycles) is critical
  • Feeder circuits require high-current protection

Dimensions & Installation Data

Modular Width (Standard 18mm Module):

  • 1P: 1 module (17.8mm)
  • 2P: 2 modules (35.6mm)
  • 3P: 3 modules (53.4mm)
  • 4P: 4 modules (71.2mm)

Фізичні розміри:

  • Height: 89.6mm (taller than standard MCB for enhanced heat dissipation)
  • Depth: 76.4mm
  • Width: 71.2mm (4P), 53.4mm (3P), 35.6mm (2P), 17.8mm (1P)

Вимоги до встановлення:

  • Mounting: Standard 35mm DIN rail per IEC/EN 60715
  • Terminal type: Larger screw terminals for high-current capacity
  • Terminal torque: M7 3.5N·m (higher than standard MCBs)
  • Wire compatibility: Suitable for high-current conductors
  • Ventilation: Ensure adequate spacing for heat dissipation in high-load applications

Important Installation Notes:

  • Use appropriately rated conductors for 80A-125A loads
  • Ensure proper torque application to prevent loose connections
  • Allow adequate ventilation space around the MCB
  • Consider ambient temperature derating for enclosed panels
VOB4-125 MCB

Certifications & Quality Standards

Відповідність міжнародним стандартам

IEC 60898-1: Circuit breakers for overcurrent protection in household and similar installations
6kA Breaking Capacity: Tested and certified short-circuit interruption rating
IP20 Protection Degree: Suitable for standard electrical enclosures
Thermal-Magnetic Trip: Proven protection technology

Manufacturing Quality

ISO 9001:2015 Certified: Quality management system certified manufacturer
100% Factory Testing: Each unit electrically tested before shipment
Підвищена довговічність: 6,000 electrical cycles, ≥20,000 endurance cycles
Full Traceability: Batch tracking and quality documentation
EU RoHS Compliant: Environmentally responsible manufacturing

Забезпечення якості

  • Rigorous testing for breaking capacity verification
  • Temperature rise testing for high-current applications
  • Endurance testing to ≥20,000 cycles
  • Continuous production quality monitoring

Installation & Selection Guide

Вибір номінального струму

How to Choose the Right Current Rating:

  1. Calculate Load Requirements:
    • Measure actual load current
    • Add safety margin (typically 125% of continuous load)
    • Врахуйте потреби майбутнього розширення
  2. 80A Rating:
    • Typical Loads: 55-64kW continuous load (400V 3-phase)
    • Best For: Sub-main distribution, medium HVAC systems
    • Приклад: 50kW central air conditioning system
  3. 100A Rating:
    • Typical Loads: 69-80kW continuous load (400V 3-phase)
    • Best For: Main distribution in medium commercial buildings
    • Приклад: Office building main distribution board
  4. 125A Rating:
    • Typical Loads: 86-100kW continuous load (400V 3-phase)
    • Best For: Large commercial main distribution, industrial feeders
    • Приклад: Shopping center main incoming breaker

Pole Configuration Selection

1-Pole (1P): Single-phase loads, 230V/240V circuits
2-Pole (2P): Single-phase loads with neutral protection, 230V/240V
3-Pole (3P): Three-phase loads without neutral, 400V/415V
4-Pole (4P): Three-phase loads with neutral protection, 400V/415V

Most Common: 3P and 4P configurations for commercial/industrial three-phase systems


Why VIOX Electric for High-Current MCBs?

Specialized High-Current Expertise

  • Extensive experience in 80A-125A MCB manufacturing
  • Advanced thermal management design for high-load applications
  • Enhanced contact materials for superior electrical performance
  • Rigorous testing protocols for high-current applications

Manufacturing Capabilities

  • ISO 9001:2015 certified production facility
  • Advanced automated assembly lines
  • In-house testing laboratory with high-current test equipment
  • Consistent quality control for every unit

Підтримка клієнтів

  • Pre-Sales: Application engineering support, load calculation assistance
  • Technical: Detailed specifications, CAD drawings, installation guidance
  • After-Sales: Technical troubleshooting, warranty support
  • Training: Product training for distributors and contractors

Supply Flexibility

  • Small sample orders for testing and evaluation
  • Large volume orders for projects and distributors
  • Mixed configurations in single orders
  • Custom labeling and packaging options

How to Order VOB4-125 MCB

Model Numbering System: VOB4-125 [Poles] [Curve] [Rating]

Ordering Examples:

  • VOB4-125 3P C 100A – 3-Pole, Type C curve, 100A rated current
  • VOB4-125 4P C 125A – 4-Pole, Type C curve, 125A rated current
  • VOB4-125 2P D 80A – 2-Pole, Type D curve, 80A rated current

Ordering Checklist:

  1. ☐ Number of poles (1P, 2P, 3P, 4P)
  2. ☐ Trip curve type (C or D)
  3. ☐ Rated current (80A, 100A, or 125A)
  4. ☐ Quantity required
  5. ☐ Voltage system (230V/400V or 240V/415V)
  6. ☐ Project timeline and delivery requirements

Get Your Quote Today

Contact VIOX Electric – High-Current MCB Specialist

For Electrical Contractors:

  • Project-specific quotations
  • Технічна підтримка додатків
  • Fast delivery for urgent projects
  • Mixed ratings and configurations available

For Panel Builders & Distributors:

  • Volume pricing tiers
  • Distributor partnership programs
  • Technical training and support
  • Custom labeling options

For Engineers & Specifiers:

  • Technical datasheets and certifications
  • CAD drawings and panel layout support
  • Application engineering consultation
  • Sample requests for testing

Часті запитання (FAQ)

Q: What’s the difference between VOB4-125 and standard 63A MCBs?
A: VOB4-125 is designed for high-current applications (80A-125A) with enhanced electrical durability (6,000 cycles vs. 4,000) and superior endurance (≥20,000 cycles). It’s used in main distribution boards, while 63A and below are typically for branch circuits.

Q: Can I use VOB4-125 as a main breaker for a commercial building?
A: Yes, the VOB4-125 is ideal for main or sub-main distribution in commercial buildings. Choose the current rating based on your calculated load requirements plus safety margin.

Q: What wire size should I use with VOB4-125?
A: Wire sizing depends on local electrical codes and installation conditions. For 125A, typically 25mm² to 35mm² copper conductors are required. Consult local codes or our technical team for specific recommendations.

Q: Is VOB4-125 suitable for three-phase systems?
A: Yes, VOB4-125 is available in 3P and 4P configurations specifically for three-phase 400V/415V systems, commonly used in commercial and industrial installations.

Q: What’s the lead time for bulk orders?
A: Standard lead time is 2-4 weeks for volume orders. Contact our sales team for urgent requirements or large projects.

Q: Do you provide installation training?
A: Yes, we offer technical training for distributors and electrical contractors. Contact us for training schedules and materials.


Related VIOX Circuit Protection Products

VOB4-63 Series (1A-63A): Standard current MCBs for branch circuit protection
MCCB Series: Molded case circuit breakers up to 1600A for higher ratings
RCCB/RCBO: Residual current protection with earth leakage detection
ACB Series: Air circuit breakers for main distribution up to 6300A
Changeover Switches: Manual and automatic transfer switches
SPD Devices: Surge protection for sensitive equipment

[VIEW ALL CIRCUIT PROTECTION PRODUCTS →]


Download Resources

  • 📄 VOB4-125 Technical Datasheet (PDF) – Complete specifications
  • 📄 Installation & Wiring Guide (PDF) – Professional installation instructions
  • 📄 IEC 60898-1 Compliance Certificate – Certification documentation
  • 📄 CAD Drawings (DWG/DXF) – For panel layout and design
  • 📄 Load Calculation Guide (PDF) – How to size high-current MCBs
  • 📄 Complete VIOX MCB Product Catalog – Full product range

[DOWNLOAD ALL RESOURCES]


Product Comparison Table

Модель Поточний діапазон Пропускна здатність Electrical Cycles Найкраща заявка
VOB3-63 1A-63A 4.5kA/6kA 4,000 Branch circuits, final loads
VOB4-63 1A-63A 6kA/10kA 4,000 Industrial branch circuits
VOB4-125 80A-125A 6 кА 6,000 Main/sub-main distribution

VOB4-125 High-Current MCB is manufactured by VIOX Electric Co., Ltd., an ISO 9001:2015 certified manufacturer specializing in low-voltage electrical protection devices. With decades of experience in high-current circuit protection, VIOX Electric provides reliable solutions for commercial, industrial, and residential main distribution applications worldwide.

Супутні товари

Запитайте пропозицію зараз