The VIOX FCV18-01/02 Single-Phase Voltage Relay protects equipment from over/undervoltage. Features AC/DC 12-240V power, adjustable thresholds, and time delay. Choose manual reset (FCV18-01) or auto-reset with hysteresis (FCV18-02). DIN rail mountable for easy installation. Ideal for industrial, commercial and residential use.
Надішліть свої вимоги, і ми надамо вам пропозицію протягом 12 годин
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Introduction to the FCV18-01/02 Single-Phase Voltage Relay
The FCV18-01/02 is a high-performance single-phase voltage relay designed to provide reliable protection against overvoltage and undervoltage conditions in electrical systems. Available in two models—FCV18-01 with manual resetting and FCV18-02 with auto resetting—this versatile relay offers comprehensive monitoring capabilities for a wide range of applications across industrial, commercial, and residential settings.
With its advanced monitoring features and robust construction, the FCV18-01/02 single-phase voltage relay ensures optimal protection for valuable electrical equipment, preventing damage caused by voltage fluctuations and improving overall system reliability.
Key Features of the FCV18-01/02 Single-Phase Voltage Relay
- Comprehensive Voltage Monitoring: Continuous monitoring for both overvoltage and undervoltage conditions
- Універсальний блок живлення: Wide operating range from 12V to 240V AC/DC
- User-Friendly Installation: Easy setup with clear wiring diagrams printed on the product
- Enhanced Protection: Strong anti-interference capability ensuring reliable operation in noisy electrical environments
- Two Model Options:
- FCV18-01: Manual resetting functionality
- FCV18-02: Auto resetting functionality with adjustable hysteresis
- Візуальні індикатори стану: Зелений світлодіод для індикації живлення та червоний світлодіод для індикації стану реле
- Precision Control: Adjustable time delay and voltage thresholds with high accuracy
- Компактний дизайн: Space-saving dimensions of 90mm×18mm×64mm, perfect for DIN rail mounting
Technical Specifications of the FCV18-01/02 Single-Phase Voltage Relay
Технічні характеристики | |
---|---|
Вхідний термінал | A1-A2 |
Діапазон напруги | AC 230V / DC24V / AC/DC 12-240V |
Енергоспоживання | ЗМІННИЙ СТРУМ 3,5 В / ПОСТІЙНИЙ СТРУМ 2,0 ВТ |
Допуск по напрузі | -15% ~ +10% |
Індикація подачі | Зелений світлодіод |
Індикація реле | Червоний світлодіод |
Часовий діапазон | 0.1s-20s |
Спосіб налаштування | Кнопка |
Відхилення налаштування | 0.1% |
Measurement Accuracy | ≤1% / ±1V |
Температурний коефіцієнт | 0,05%/°C, при=20°C (0,05%/°F, =68°F) |
Вихідний контакт | 1×SPDT |
Номінальний струм | 1×16A |
Механічне життя | 1×10⁷ |
Електричне життя | 1×10⁵ |
Температура навколишнього середовища | -20 ... +60 °C / -40 ... +85 °C |
Монтаж | DIN-рейка EN/IEC 60715 |
Рейтинг IP | IP20 |
Довжина зачистки | 7 мм (0,28 дюйма) |
Встановлена висота над рівнем моря | ≤2200m |
Рівень забруднення | 2 |
Максимальний розмір кабелю | AWG13-20 0.4N-m |
Розміри | 90мм×18мм×64мм |
Вага | Близько 90 г |
Стандарти | GB/T 14048.5, IEC60947-5-1, EN6812-1 |
FCV18-01/02 Voltage Relay Models: Understanding the Differences
FCV18-01: Manual Resetting Single-Phase Voltage Relay
The FCV18-01 model provides manual resetting functionality, making it ideal for applications where human intervention is preferred or required after a voltage event. This model offers precise control over voltage thresholds with adjustable Umax and Umin settings, along with a configurable time delay (Tt) for response customization.
When the monitored voltage exceeds the set Umax or falls below the set Umin threshold for longer than the defined time delay, the relay changes state. To resume normal operation after a trip, manual resetting is required, ensuring that the system is not automatically restarted without proper verification.
FCV18-02: Auto Resetting Single-Phase Voltage Relay with Hysteresis
The FCV18-02 model offers auto resetting functionality with adjustable hysteresis (H), providing enhanced protection for systems that require automatic recovery. This model is particularly valuable in remote locations or applications where immediate recovery is preferred after voltage conditions return to normal.
The auto-resetting feature includes programmable hysteresis, creating separate recovery thresholds (Umax*(1-H)% for overvoltage and Umin*(1+H)% for undervoltage) that prevent rapid cycling of the relay when voltage fluctuates near the threshold values. It’s important to ensure that Umax > Umax*(1-H)% > Umin*(1+H)% > Umin for proper operation.
Voltage Setting Options for FCV18-01/02 Single-Phase Voltage Relays
The FCV18-01/02 single-phase voltage relay offers flexible voltage setting options to accommodate various electrical systems:
Voltage Settings | ||
---|---|---|
Код | Setting Voltage | Monitoring Voltage |
A48 | AC20-80V | AC15-100V |
A220 | AC165-260V | AC140-270V |
A240 | AC65-260V | AC50-270V |
D12 | DC9-18V | DC7-25V |
D48 | DC20-80V | DC15-100V |
D240 | DC65-260V | DC50-270V |
When ordering, use the model code format FCV18-XX-YZZ, where:
- XX: Function type (01 for manual resetting, 02 for auto resetting)
- Y: Supply voltage (A for AC, D for DC, W for AC/DC)
- ZZ: Voltage range (48, 220, 240, 12, etc.)
For example, FCV18-01-A240 indicates a manual resetting model with AC65-260V setting range.
Function Chart: Understanding Operational Behavior
FCV18-01 (Manual Resetting) Operation
The function chart for the FCV18-01 model illustrates how the relay responds to voltage fluctuations:
- When input voltage (Un) exceeds Umax or falls below Umin for a period longer than the time delay (Tt), the relay changes state
- The relay maintains this state until manually reset, even if voltage returns to the normal range
- Time delay (Tt) provides protection against momentary voltage fluctuations
FCV18-02 (Auto Resetting) Operation
The function chart for the FCV18-02 model demonstrates its auto-resetting behavior with hysteresis:
- When input voltage (Un) exceeds Umax or falls below Umin for a period longer than the time delay (Tt), the relay changes state
- The relay automatically resets when voltage returns to Umax*(1-H)% (for overvoltage) or Umin*(1+H)% (for undervoltage)
- Hysteresis (H) setting prevents relay chatter when voltage fluctuates near threshold values
- Important: Always ensure Umax > Umax*(1-H)% > Umin*(1+H)% > Umin
Wiring and Installation Guidelines
Proper wiring is essential for the reliable operation of the FCV18-01/02 single-phase voltage relay:
- Power Connection: Підключіть джерело живлення до клем A1 та A2
- Output Connection: Connect controlled device to terminals 14 (normally open), 11 (common), and 12 (normally closed)
- Монтаж на DIN-рейку: Install the relay on a standard DIN rail EN/IEC 60715
- Екологічні міркування: Ensure installation location meets the specified ambient temperature range (-20 to +60°C for operation)
- Вибір кабелю: Use appropriate cable size (AWG13-20) with proper stripping length (7mm)
Applications of the FCV18-01/02 Single-Phase Voltage Relay
The FCV18-01/02 single-phase voltage relay is suitable for a wide range of applications across various industries:
Промислове застосування
- Protection of sensitive manufacturing equipment
- Motor protection against voltage fluctuations
- Control systems for industrial processes
- Automation equipment protection
- Промислові системи розподілу електроенергії
Комерційне застосування
- HVAC system protection
- Commercial refrigeration equipment
- Захист офісного обладнання
- Building management systems
- Elevator and escalator control systems
Житлові програми
- Home appliance protection
- Residential power systems
- Smart home systems
- Solar power installations
- Backup power systems
Спеціалізовані програми
- Telecommunications equipment protection
- Medical equipment safeguarding
- Laboratory instruments
- Agriculture and irrigation systems
- Remote monitoring stations
Benefits of Using the FCV18-01/02 Single-Phase Voltage Relay
Захист обладнання
The primary benefit of implementing the FCV18-01/02 single-phase voltage relay is the protection of valuable electrical equipment from damage caused by voltage fluctuations. By monitoring for both overvoltage and undervoltage conditions, the relay can prevent costly equipment failures and extend the operational lifespan of connected devices.
System Reliability
With its precise voltage monitoring and quick response time, the FCV18-01/02 significantly improves system reliability by preventing unexpected shutdowns and equipment malfunctions. The adjustable time delay feature allows for customization based on specific application requirements, filtering out momentary fluctuations while responding appropriately to sustained voltage issues.
Cost Savings
By protecting equipment from voltage-related damage, the FCV18-01/02 single-phase voltage relay helps reduce maintenance costs, prevent production downtime, and extend equipment lifespan. This translates to significant cost savings over time, making it a wise investment for any electrical system.
Easy Setup and Operation
The user-friendly design of the FCV18-01/02, with its clear wiring diagrams and simple adjustment mechanisms, ensures easy installation and operation. This reduces setup time and minimizes the possibility of installation errors, allowing for quick implementation in various applications.
Comparison: FCV18-01 vs. FCV18-02 Single-Phase Voltage Relays
Особливість | FCV18-01 | FCV18-02 |
---|---|---|
Resetting Method | Manual | Automatic |
Hysteresis | Fixed | Adjustable (H setting) |
Найкраще для | Applications requiring human verification before restart | Remote locations and systems needing automatic recovery |
Recovery Thresholds | N/A (manual reset required) | Umax*(1-H)% and Umin*(1+H)% |
Adjustment Controls | Umax, Umin, Tt | Umax, Umin, Tt, H |
Обслуговування та усунення несправностей
The FCV18-01/02 single-phase voltage relay requires minimal maintenance due to its robust design and high-quality components. However, periodic checks are recommended to ensure optimal performance:
Регулярне технічне обслуговування
- Visually inspect the relay for any signs of damage or overheating
- Check connection terminals for tightness
- Переконайтеся, що світлодіодні індикатори працюють належним чином
- Test relay operation periodically in systems where infrequent activation occurs
Усунення поширених проблем
- Relay Not Activating: Check power supply connections and verify voltage is within operating range
- Frequent Tripping: Adjust time delay (Tt) or hysteresis (H) settings for less sensitivity to brief fluctuations
- No LED Indicators: Verify power connection and check for internal fuse issues
- Unexpected Auto-Reset: For FCV18-02, check hysteresis settings and ensure proper threshold hierarchy
Інформація для замовлення
To order the FCV18-01/02 single-phase voltage relay, use the following model code format:
FCV18-XX-YZZ
Де:
- ХХ: Function type
- 01 = Manual resetting
- 02 = Auto resetting
- Y: Напруга живлення
- A = AC voltage
- D = DC voltage
- W = AC/DC voltage
- ZZ: Діапазон напруги
- 48 = 20-80V range
- 220 = 165-260V range
- 240 = 65-260V range
- 12 = 9-18V range (DC only)
Example: FCV18-01-A240 W indicates a manual resetting relay with AC/DC 12-240V wide range power supply.
Висновок
The FCV18-01/02 single-phase voltage relay represents a reliable and versatile solution for voltage protection across diverse applications. With its comprehensive monitoring capabilities, flexible configuration options, and robust design, this relay offers exceptional value for protecting electrical systems and equipment from voltage-related damage.
Whether you choose the manual resetting FCV18-01 model for applications requiring human verification or the auto-resetting FCV18-02 model with hysteresis for automatic recovery, you’ll benefit from precise voltage monitoring, easy installation, and long-term reliability.
By integrating the FCV18-01/02 single-phase voltage relay into your electrical systems, you can significantly reduce the risk of equipment damage, minimize downtime, and enhance overall system reliability—making it an essential component for any comprehensive electrical protection strategy.
Note: The above information is subject to change without further notice. Always refer to the latest product documentation for the most up-to-date specifications.