VKL11F Typ F EV 4P jordfelsbrytare (RCCB)

The VIOX VKL11F Type F EV 4P Residual Current Circuit Breaker (RCCB) is purpose-built for electric vehicle charging safety. It detects AC, pulsed DC, and mixed-frequency residual currents, plus crucial 6mA smooth DC leakage. This short-time delayed (10-300ms) RCCB minimizes false trips, complying with EN61008-1 and EN62423.

Skicka dina krav, vi kommer att offerera för dig inom 12 timmar

The VKL11F Residual Current Circuit Breaker Type F EV represents the cutting edge in electrical safety technology specifically engineered for electric vehicle (EV) charging applications. As the electric vehicle market continues to expand, ensuring safe and reliable charging infrastructure becomes increasingly critical. The VKL11F RCCB stands as an essential safety component that protects both your valuable electrical systems and the people who interact with them.

What is the VKL11F RCCB Type F EV?

The VKL11F is a specialized Residual Current Circuit Breaker (RCCB) that has been specifically developed to address the unique electrical protection requirements in EV charging environments. This device monitors electrical circuits for imbalances and automatically disconnects the circuit when a potentially dangerous situation is detected, preventing electrical shocks and fires.

Unlike standard RCCBs, the VKL11F Type F EV is designed to detect and respond to both AC and DC residual currents, making it particularly suited for the complex electrical environments associated with modern electric vehicle charging systems. It meets and exceeds the stringent requirements of EN61008-1 and EN62423 standards, ensuring maximum safety and reliability.

Key Features of the VKL11F RCCB

Specialized EV Charging Protection

The VKL11F Type F EV RCCB has been meticulously engineered for electric vehicle charging systems. It can detect both AC and DC residual currents in accordance with EN61008-1 and EN62423 standards, providing comprehensive protection specifically tailored for EV charging stations.

Mixed Frequency Detection

One of the standout features of the VKL11F RCCB is its ability to detect residual currents with mixed frequencies, which differentiates it from standard 50Hz protection devices. This capability is crucial in EV charging applications, where power electronics can generate currents at various frequencies.

Enhanced Surge Current Strength

The VKL11F RCCB features short-time delayed operation and increased surge current strength, significantly reducing the risk of false tripping. This ensures reliable operation even in challenging electrical environments commonly found in EV charging setups.

Multiple Tripping Sensitivity Options

With tripping sensitivity of 30mA for sinusoidal AC currents and pulsating DC, as well as 6mA for smooth DC (RDC-PD), the VKL11F provides comprehensive protection against various types of fault currents that may occur in EV charging circuits.

Tekniska specifikationer

Standard IEC/EN 61008-1 & EN62423
Modell nr. VKL11F F EV
Stolpar 2P, 4P
Märkström In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Märkkänslighet I∆n 30 mA
Tröskelvärde för DC-utlösning 6mA
Märkspänning Ue 2P: 240V 4P: 415V
Isolationsspänning Ui 500V
Nominell frekvens 50/60 Hz
Nominell kvarvarande drag- och brytförmåga I∆m 500A (In=16A, 25A, 32A, 40A)
630A(In=63A), 800A(In=80A), 1000A(In=100A)
Elektriska funktioner Short-circuit current Inc/Icn 6000A, 10000A
Nominell drag- och brotthållfasthet Im 1500 A
Maximal strömstyrka 3 kA (8/20 μs) skydd mot överspänningsström
Typ (vågform för det jordläckage som avkänns) AC, A
Smidig DC 6mA
Utlösningstid Short time delayed
10ms-300ms
Rasttid under I∆n (G type)
Nominell spänning för impulstålighet (1,2/50) Uimp 4kV
Dielectric test voltage at ref. Freq. for 1 min 2.5
Mekaniska egenskaper Grad av förorening 2
Elektrisk livslängd ≥ 2000
Mekanisk livslängd ≥ 2000
Indikator för felström Ja
Terminalens skyddsgrad IP20
Omgivningstemperatur (med dagligt genomsnitt≤35°C) -25°C till 55°C
Förvaringstemperatur -40°C till 70°C
Kabel/Samlingsskena av stifttyp Typ av terminalanslutning
Plintstorlek upptill/nertill för kabel 25-35 mm²
18-3/18-2 AWG
Plintstorlek upptill/nertill för samlingsskena 10/16 mm²
18-8/18-5 AWG
Installation 2.5 N.m
Installation Åtdragningsmoment 22 tum-pund.
Montering På DIN-skena EN 60715 (35 mm) med hjälp av snabbfästanordning
Anslutning Från topp till botten

VKL11F Type F EV Residual Current Circuit Breaker (RCCB) Dimension

VKL11F Type F EV Residual Current Circuit Breaker (RCCB) Dimension

Tripping Sensitivity & Performance

The VKL11F RCCB offers superior protection with its carefully calibrated tripping sensitivity:

  • Sinusoidal AC Detection: 30mA at 50Hz, ensuring protection against standard alternating current faults
  • Pulsating DC Detection: Responds to pulsating direct current that may result from power conversion in EV charging
  • Smooth DC Detection: 6mA threshold for smooth DC residual currents (RDC-PD), providing protection against DC leakage which is critical in EV charging applications

The device features short-time delayed (G) tripping operation with response times between 10ms-300ms, balancing rapid protection with immunity to nuisance tripping from transient events.

Wave Form Detection Capabilities

AC Class Protection

Tripping is ensured for slowly increasing sinusoidal AC residual currents, providing protection against the most common form of fault currents.

A Class Protection

The VKL11F also offers protection against sinusoidal AC residual currents and pulsed DC residual currents, whether applied suddenly or increasing slowly, addressing a wider range of potential faults.

Smooth DC 6mA Protection

A standout feature of the VKL11F is its ability to detect smooth DC residual currents with a switch-off threshold at max 6 mA, which is essential for modern EV charging systems with power electronics.

Installation och mått

The VKL11F RCCB is designed for easy installation on standard 35mm DIN rails (EN 60715) using a convenient fast clip device. With comprehensive dimensional specifications provided, integrating this protection device into your electrical panels or EV charging stations is straightforward.

Available in both 2-pole and 4-pole configurations, the VKL11F can be adapted to various electrical system requirements. Connections can be made from both top and bottom terminals, offering flexibility in installation design.

Driftförhållanden

The VKL11F RCCB is built to perform reliably across a wide range of environmental conditions:

  • Operating temperature range: -25°C to 55°C
  • Storage temperature range: -40°C to 70°C
  • IP20 terminal protection degree
  • Föroreningsgrad: 2

This robust design ensures dependable operation even in challenging installation environments, making the VKL11F suitable for both indoor and outdoor EV charging applications (when appropriately enclosed).

Compliance and Certifications

The VKL11F RCCB meets or exceeds multiple international standards and certifications:

  • IEC/EN 61008-1 (general requirements for RCCBs)
  • EN62423 (specific requirements for F-type and B-type RCCBs)
  • UKCA and CE certified, ensuring compliance with rigorous European safety standards

These certifications confirm that the VKL11F provides the highest levels of safety and reliability for EV charging infrastructure.

Applications of VKL11F RCCB

The VKL11F Residual Current Circuit Breaker is ideally suited for:

  • Residential EV Charging Stations: Ensuring safe home charging for electric vehicle owners
  • Commercial Charging Infrastructure: Protecting public and workplace charging stations
  • Fleet EV Charging Facilities: Safeguarding large-scale charging operations for electric vehicle fleets
  • Integrated EV Supply Equipment (EVSE): As a critical component in complete charging solutions

Anywhere electric vehicles are being charged, the VKL11F provides the specialized protection needed to ensure safety and reliability.

Why Choose the VKL11F RCCB for EV Charging Applications?

Specialiserat skydd

Unlike general-purpose RCCBs, the VKL11F is specifically designed to address the unique electrical characteristics and protection requirements of EV charging systems, offering superior safety compared to standard protection devices.

Reliability in Complex Electrical Environments

The ability to detect mixed frequency residual currents and smooth DC leakage makes the VKL11F ideal for the complex electrical environments created by power electronics in charging equipment.

Reduced False Tripping

With short-time delayed operation and enhanced surge current strength, the VKL11F minimizes the risk of nuisance tripping while maintaining comprehensive protection, ensuring that charging sessions complete successfully without unnecessary interruptions.

Compliance with Latest Standards

By meeting the requirements of EN61008-1 and EN62423, the VKL11F ensures that your EV charging infrastructure complies with the latest safety standards and regulations, future-proofing your investment.

Slutsats

The VKL11F Residual Current Circuit Breaker Type F EV represents an essential safety component for any electric vehicle charging installation. Its specialized design for EV applications, comprehensive protection capabilities, and compliance with international standards make it the ideal choice for ensuring the safety and reliability of your EV charging infrastructure.

By installing the VKL11F RCCB, you’re not just meeting regulatory requirements – you’re making a commitment to the highest levels of electrical safety for your customers, employees, and equipment. As the electric vehicle revolution continues to gain momentum, choosing the right protection devices becomes increasingly critical, and the VKL11F stands ready to meet these challenges.

For more information about the VKL11F RCCB or to discuss your specific EV charging protection needs, please contact our technical support team.

Relaterade produkter

Be om offert nu