VIOX FCT18-Bta Timerrelä med fördröjning och summastyrsignal
The VIOX FCT18-Bta Off-Delay Timer Relay offers precise OFF-delay timing (0.1s-100 days), summing NPN/PNP control signal pulses. Features <0.5% error, 1 or 2 SPDT contacts, DIN rail mount, and AC/DC 12-240V support. Ideal for industrial automation needing cumulative OFF-delay timing.
Skicka dina krav, vi kommer att offerera för dig inom 12 timmar
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Introduction to the FCT18-Bta Off-delay Timer Relay
The VIOX FCT18-Bta is an advanced off-delay timer relay designed for precise timing control in industrial automation, manufacturing, and process control systems. This versatile timing relay offers exceptional flexibility with its summation control signal feature, allowing complex timing sequences through the cumulative addition of multiple input signals.
Built for reliability in demanding environments, the FCT18-Bta provides accurate timing functions with an error margin of less than 0.5%, making it ideal for applications where precision is critical. Its wide time setting range from 0.1 seconds to 100 days covers virtually any industrial timing requirement, while the comprehensive power supply compatibility (12-240 VAC/DC) ensures seamless integration into almost any electrical system.
Understanding Off-delay Timer Relay Functionality
The FCT18-Bta operates on the off-delay timer principle, one of the most widely used timing functions in industrial control systems. Unlike standard timers, an off-delay timer relay maintains its output in an active state while the input signal is present and continues to hold this state for a predetermined period after the input signal is removed.
How the FCT18-Bta Off-delay Function Works:
- Initialt tillstånd: When power (Un) is applied to the relay, the output remains inactive.
- Triggering: When the control signal (S) is activated, the output relay (R) immediately switches to active state.
- Off-delay Timing: When the control signal (S) is removed, the timer starts counting.
- Summation Feature: With the unique summation control capability, the FCT18-Bta adds together multiple input pulses (t1 + t2 + … + tx) to create a total timing period (T).
- Completion: After the set delay time expires, the output relay returns to its inactive state.
This timing behavior makes the FCT18-Bta particularly valuable in applications requiring precise equipment shutdown sequences, cooling periods, or delayed process transitions.
Key Features and Benefits of the FCT18-Bta Off-delay Timer Relay
Extensive Time Range Flexibility
- Wide timing spectrum: From rapid 0.1-second intervals to extended 100-day periods
- 10 selectable time ranges: 0.1-1s, 1-10s, 0.1-1m, 1-10m, 0.1-1hr, 1-10hr, 0.1-1day, 1-10day, 3-30day, 10-100day
- Precise ratio adjustment: 18 ratio settings from 10% to 100% for fine-tuning within each time range
Superior Electrical Specifications
- Universal power supply: Compatible with 12 to 240 VAC/DC systems
- Low power consumption: Only 3.5VA (AC) or 2.0W (DC)
- Generous voltage tolerance: -15% to +10%
- Reliable contact ratings: Up to 16A per contact for demanding loads
Enhanced Durability and Performance
- Impressive mechanical life: 10 million operations
- Substantial electrical life: 1 million operations at rated load
- Excellent temperature stability: 0.05%/°C temperature coefficient
- High timing accuracy: Time deviation of just 0.1%
- Upprepningsnoggrannhet: Within 0.5% for consistent performance
Robust Environmental Specifications
- Brett driftstemperaturområde: -20°C to +60°C (-4°F to +140°F)
- Storage temperature range: -40°C to +85°C (-40°F to +185°F)
- IP20 ingress protection: Protection against solid objects larger than 12mm
- High-altitude capability: Operates reliably at elevations up to 2200m
- Montering på DIN-skena: Standard EN/IEC 60715 compatibility for easy installation
User-friendly Design
- Integrated LED indicators: Green for power supply, Red for relay status
- Intuitive dial settings: Easily adjustable time and ratio controls
- Kompakta mått: 90mm × 18mm × 64mm space-efficient design
- Lightweight construction: Approximately 90g for easy handling
- Clear wiring diagrams: Printed on the device for simple installation
Tekniska specifikationer
Modellvarianter
The FCT18-Bta is available in multiple configurations based on the following coding system:
FCT18-Bta (1) (2) (3) (4)
- Funktion
- Bta: Off-delay with summation control
- Typ av utgång
- 1: 1CO contact (one changeover contact)
- 2: 2CO contacts (two changeover contacts)
- Matningsspänning
- A: AC 230V
- D: DC 24V
- W: AC/DC 12-240V (universal power supply)
- Styrsignal
- N: NPN (negative switching)
- P: PNP (positive switching)
Detailed Specifications Table
Parameter | FCT18-Bta1 | FCT18-Bta2 |
---|---|---|
Ingångsterminal | A1-A2 | A1-A2 |
Spänningsintervall | AC 230V / DC24V / AC/DC 12-240V | AC 230V / DC24V / AC/DC 12-240V |
Strömförbrukning | AC 3,5VA/ DC 2,0W | AC 3,5VA/ DC 2,0W |
Spänningstolerans | -15% ~ +10% | -15% ~ +10% |
Indikation för matning | Grön LED | Grön LED |
Reläindikering | Röd LED | Röd LED |
Tidsintervall | 0,1 s-100 dagar | 0,1 s-100 dagar |
Tidsinställning | Knapp | Knapp |
Tidsavvikelse | 0.1% | 0.1% |
Upprepningsnoggrannhet | 0.5% | 0.5% |
Temperaturkoefficient | 0,05%/°C, vid=20°C (0,05%/°F, vid=68°F) | 0,05%/°C, vid=20°C (0,05%/°F, vid=68°F) |
Utgående kontakt | 1×SPDT | 2×SPDT |
Nominell ström | 1×16A | 2×16A |
Mekanisk livslängd | 1×10⁷ | 1×10⁷ |
Elektrisk livslängd | 1×10⁵ | 1×10⁵ |
Omgivande temperatur | -20 ... +60°C / -40 ... +85°C | -20 ... +60°C / -40 ... +85°C |
Montering | DIN-skena EN/IEC 60715 | DIN-skena EN/IEC 60715 |
IP-klassning | IP20 | IP20 |
Strippningslängd | 7 mm (0,28 tum) | 7 mm (0,28 tum) |
Installerad höjd | ≤2200m | ≤2200m |
Föroreningsnivå | 2 | 2 |
Max kabelstorlek | AWG13-20 0,4N-m | AWG13-20 0,4N-m |
Dimension | 90 mm × 18 mm × 64 mm | 90 mm × 18 mm × 64 mm |
Vikt | ca 90 g | ca 90 g |
Standarder | GB/T 14048.5, IEC60947-5-1, EN6812-1 | GB/T 14048.5, IEC60947-5-1, EN6812-1 |
Installations- och kabeldragningsguide
Alternativ för kabeldragning
The FCT18-Bta offers two control signal options to accommodate different system architectures:
NPN-konfiguration
- Input terminals: A1 (DC+ / AC L), A2 (DC- / AC N), S (Signal)
- Control signal connection between S and A2
- Output terminals: 11, 12, 14 for single contact model
- Output terminals: 11, 12, 14, 21, 22, 24 for dual contact model
PNP-konfiguration
- Input terminals: A1 (DC+ / AC L), A2 (DC- / AC N), S (Signal)
- Control signal connection between S and A1
- Output terminals: 11, 12, 14 for single contact model
- Output terminals: 11, 12, 14, 21, 22, 24 for dual contact model
Riktlinjer för installation
- Mount the relay on a standard 35mm DIN rail according to EN/IEC 60715
- Säkerställ korrekt ventilation runt enheten
- Maintain minimum clearance of 10mm from adjacent devices
- Use wire stripping length of 7mm (0.28in)
- Tighten terminal screws to 0.4N·m torque
- Select appropriate wire gauge (AWG13-20)
Procedur för inställning av tid
The FCT18-Bta features an intuitive dual-dial setting system for precise time control:
Step 1: Select Time Range
Using the upper rotary switch, select one of the 10 time range options:
- 0.1-1s
- 1-10s
- 0.1-1m
- 1-10m
- 0,1-1 timme
- 1-10 timmar
- 0,1-1 dag
- 1-10 dagar
- 3-30 dagar
- 10-100 dagar
Step 2: Set Ratio Percentage
Using the lower rotary switch, select the percentage of the time range (from 10% to 100%):
- 10%, 15%, 20%, 25%, 30%, 35%, 40%, 45%, 50%, 55%
- 60%, 65%, 70%, 75%, 80%, 85%, 90%, 95%, 100%
Example Settings:
- For a 5-second delay: Select 1-10s range and 50% ratio
- For a 2-hour delay: Select 1-10hr range and 20% ratio
- For a 45-day delay: Select 10-100day range and 45% ratio
Dimension
Applications of the FCT18-Bta Off-delay Timer Relay
Industriell automation
- Conveyor belt control: Ensuring conveyor systems continue running for a set time after sensor signals cease
- Machine shutdown sequences: Allowing auxiliary systems to continue operating after main power is removed
- Cooling systems: Maintaining fan operation for a predetermined period after equipment shutdown
- Sequential operations: Coordinating multiple process steps with precise timing intervals
Förvaltning av byggnader
- Ventilation control: Extended fan operation in bathrooms or kitchens after light switches are turned off
- Stairwell lighting: Maintaining illumination for a comfortable exit period after button press
- Security systems: Delayed activation or deactivation of security components in access control systems
- HVAC coordination: Sequencing heating/cooling equipment operation with proper timing delays
Energiförvaltning
- Load shedding: Sequentially disconnecting non-critical loads during power constraints
- Generator systems: Coordinating cool-down periods for emergency generators
- UPS coordination: Managing orderly shutdowns during power transitions
- Solar/alternative energy: Controlling equipment timing during variable energy availability
Processtyrning
- Chemical dosing: Ensuring accurate timing in chemical addition processes
- Mixing operations: Controlling agitation timing after material additions
- Batch processing: Managing sequential operations in manufacturing processes
- Water treatment: Coordinating pump operations and treatment cycles
Special Feature: Summation Control Signal
The FCT18-Bta’s distinctive summation control capability represents a significant advancement in timer relay technology. This feature allows the relay to accumulate multiple input signals (t1 + t2 + … + tx), creating a combined delay period (T) that represents the sum of all individual signals.
This functionality is particularly valuable in applications where:
- Process variables determine optimal timing needs
- Multiple operator inputs influence timing requirements
- System events must accumulate to trigger subsequent actions
- Flexible timing adaptations are needed based on runtime conditions
Why Choose the VIOX FCT18-Bta Off-delay Timer Relay?
Överlägsen tillförlitlighet
With timing error less than 0.5%, temperature stability of 0.05%/°C, and a mechanical lifecycle of 10 million operations, the FCT18-Bta delivers consistent performance in demanding industrial environments.
Exceptionell mångsidighet
The combination of wide time ranges (0.1s to 100 days), flexible power supply options (12-240 VAC/DC), and dual control signal configurations (NPN/PNP) makes the FCT18-Bta adaptable to virtually any timing control application.
Ease of Implementation
Clear wiring diagrams printed on the device, intuitive dial controls, and standard DIN rail mounting ensure straightforward installation and setup without specialized tools or training.
Advanced Features
The summation control signal capability provides sophisticated timing control options not available in standard timer relays, allowing for complex timing sequences with minimal component requirements.
Efterlevnad och kvalitet
Manufactured to meet rigorous international standards including GB/T 14048.5, IEC60947-5-1, and EN6812-1, the FCT18-Bta ensures reliable operation and compatibility with global electrical systems.
Slutsats
The VIOX FCT18-Bta off-delay timer relay with summation control signal represents a perfect balance of precision, versatility, and reliability for industrial timing applications. Its wide range of timing options, universal power supply compatibility, and unique summation control capability make it an ideal solution for both simple and complex timing control requirements.
Whether used in manufacturing automation, building management systems, energy control applications, or process coordination, the FCT18-Bta delivers consistent, accurate timing performance in a compact, user-friendly package. With its proven reliability and advanced features, this timer relay provides engineers and system integrators with a powerful tool for implementing sophisticated timing control strategies while maintaining simplicity of installation and operation.
For more information about the FCT18-Bta off-delay timer relay or to discuss your specific timing control application needs, contact VIOX technical support or visit our website at viox.com.