ASTP-Y Tidrelä
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Skicka dina krav, vi kommer att offerera för dig inom 12 timmar
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
VIOX ASTP-Y Analog Timer
Översikt
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Viktiga funktioner
- Exakt kontroll av tidsinställning: Justerbart tidsområde från 0 till 60 sekunder med en analog ratt.
- Tillförlitlig drift: Växlar reläkontakter efter den inställda tiden och bibehåller positionen.
- Dubbla reläutgångar: Två reläutgångar med en maximal belastning på 5A vardera.
- Enkel installation: Inkluderar PF083A-sockel för DIN-skenemontering.
- Visuella indikatorer: Arbetsindikator på frontpanelen för enkel övervakning.
- Slitstark konstruktion: Utformad för långvarig prestanda med hög mekanisk och elektrisk livslängd.
- Brett spänningsintervall: Drivs med 230 VAC med en tolerans på +/-10%.
Specifikationer
CLASSIFICATION | TIMER | TIMER | ||||||
MODELL | ASTP-N | ASTP-Y | AH2-N | AH2-Y | ||||
APPEARANCE | ||||||||
DIMENSIONS | 61H×49W×70D | 88H×58W×68D | 61H×49W×70D | 88H×58W×68D | ||||
MOUNTING & SOCKET |
SURFACE(-N) | PF083A(E) PS-08 | PF083A(E) PS-08 | |||||
FLUSH(-Y) | US-08 P3G-08 | US-08 P3G-08 | ||||||
FULL TIMING RANGE | SEC:1,3,6,10,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
SEC:1,3,6,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
||||||
RATED VOLTAGE | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | ||||||
INDICATOR OPERATING | Time Operating | ON-UP Two indicator Lamp ON-UP | ||||||
CONTACT | MODELL | ASTP-N1/ ASTP-Y1 | ASTP-N2/ ASTP-Y2 | ASTP-N/ ASTP-Y | AH2-N1/ AH2-Y1 | AH2-N2/ AH2-Y2 | AH2-N/ AH2-Y | |
TIME LIMIT 1C | 5A | 5A | 5A | 5A | ||||
TIME LIMIT 2C | 5A | 5A | ||||||
INSTANTANEOUS 1C | 5A | 5A | ||||||
LIFE | MECHANICAL | 5×106 tider | 5×106 tider | |||||
ELECTRICAL | 105 tider | 105 tider | ||||||
ACCURACY | REPEAT ERROR | ±1% max | ±1% max | |||||
SETTING ERROR | ±10% max | ±10% max | ||||||
VOLTAGE ERROR | ±1% max | ±1% max | ||||||
TEMP. ERROR | ±2% max | ±2% max | ||||||
RESET TIME | 0.1 sec max | 0.1 sec max | ||||||
CONSUMED POWER | 2VA | 3VA | ||||||
AMBIENT TEMPERATURE | -10℃~+55℃ | -10℃~+55℃ | ||||||
AMBIENT HUMIDITY | 48~85%RH | 48~85%RH | ||||||
WEIGHT | 220 g | 220 g | ||||||
CONNECTION DIAGRAMS & TIMING CHART | 39A | 39B | 39C | 39D | 39E | 39F |
Tillämpningar
VIOX ASTP-Y analog timer är idealisk för en mängd olika tillämpningar inom industriell automation och mekaniska apparater. Den är lämplig för användning i kontrollpaneler, maskiner och andra system som kräver exakt tidsstyrning. Timerns robusta design och tillförlitliga prestanda gör den till ett utmärkt val för både kommersiella och industriella miljöer.
Tekniska data
- Strömförsörjning: 230 VAC +/-10%
- Utgång: Relä
- Maxbelastning: 5A
- Tidsintervall: 0–60 sekunder
- Mått: 40×50 mm
- Montering: DIN-skena, i tabellen
- Resolution: Analog urtavla
- Skyddsgrad: IP40
- Mekanisk livslängd: 5×106 tider
- Elektrisk livslängd: 105 tider
- Noggrannhet: Upprepat fel: ±1% max., Inställningsfel: ±10% max., Spänningsfel: ±1% max., Temp.fel: ±2% max.
- Återställningstid: 0,1 sek. Max.
- Förbrukad kraft: 2VA
- Omgivande temperatur: -10℃ till +55℃
- Omgivande luftfuktighet: 48% till 85% höger
- Vikt: 220 g
Anslutningsschema
VIOX ASTP-Y analog timer har ett enkelt kopplingsschema för enkel installation. Enheten börjar räkna den inställda tiden när strömförsörjningen appliceras, växlar sedan reläkontakterna och förblir i detta läge. Relä A1 arbetar enligt den inställda tiden på panelen, medan relä A2 arbetar enligt timerns strömförsörjning.
Utgångslägen
När strömförsörjningen appliceras börjar enheten räkna den inställda tiden och växlar sedan reläkontakterna, vilket bibehåller detta läge. Relä A1 arbetar enligt den inställda tiden på panelen, och relä A2 arbetar enligt timerns strömförsörjning. Nedan följer funktionsschemat: