VKL11 tip A EV 4P odklopnik preostalega toka (RCCB)
The VIOX VKL11 Type A EV 4P Residual Current Circuit Breaker (RCCB) is specifically engineered for Mode 3 EV charging safety. It protects against AC and pulsed DC residual currents, in . includes critical 6mA smooth DC detection. This 2-pole RCCB ensures comprehensive protection, complying with IEC/EN 61008-1 and IEC 62955.
Pošljite svoje zahteve, ponudbo vam bomo posredovali v 12 urah
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Introduction to the VKL11 Residual Current Circuit Breaker
The VKL11 Residual Current Circuit Breaker (RCCB) Type A EV represents VIOX’s commitment to electrical safety innovation. Specifically designed for Mode 3 EV charging applications, this premium safety device offers comprehensive protection against residual currents in both AC and DC forms, making it an essential component for modern electrical installations and EV charging infrastructure.
As electric vehicles become increasingly common, the need for specialized electrical safety devices grows proportionally. The VKL11 RCCB meets this demand with its Type A classification, explicitly engineered to detect AC sinusoidal residual currents and pulsed DC residual currents, providing critical protection for both people and equipment in EV charging environments.
Why Choose the VKL11 Residual Current Circuit Breaker?
The VKL11 RCCB stands out in the market for several compelling reasons:
- Specialized EV Protection: Purpose-built for EV charging systems, offering protection that standard RCCBs cannot provide
- Dual Residual Current Detection: Monitors both AC sinusoidal and DC pulsed residual currents
- Instantaneous Tripping: Ensures immediate response to fault conditions without time-delay
- Multiple Rating Options: Available in various current ratings from 16A to 100A
- Compliance Assured: Fully certified to IEC/EN 61008-1 and IEC 62955 standards
- Robust Construction: Built to withstand demanding environmental conditions from -25°C to 55°C
Technical Specifications of the VKL11 RCCB
The VKL11 Residual Current Circuit Breaker is developed in strict accordance with IEC/EN 61008-1 and IEC 62955 standards, ensuring the highest level of electrical safety performance. Here’s a detailed breakdown of its technical parameters:
Key Technical Parameters
Technical Parameters | |
---|---|
Model No. | VKL11 A EV |
Stebri | 2P, 4P |
Rated current In | 16A, 25A, 32A, 40A, 63A, 80A, 100A |
Rated Sensitivity I∆n | 10mA(2P/4P 16A-40A), 30mA, 100mA, 300mA |
DC tripping threshold | 6mA |
Rated voltage Ue | 2P: 240V 4P: 415V |
Insulation voltage Ui | 500V |
Rated frequency | 50/60 Hz |
Electrical Features
Electrical Features | |
---|---|
Rated residual making and breaking capacity I∆m | 630A(In=63A), 800A(In=80A), 1000A(In=100A) |
Short-circuit current Inc/I△c | 6000A, 10000A |
Type (wave form of the earth leakage sensed) | AC: A Smooth DC 6mA |
Tripping time | Instantaneous |
Break time under I∆n | ≤ 100ms (Normal type) |
Rated impulse withstand voltage(1,2/50) Uimp | 6kV |
Dielectric test voltage at ind. Freq. for 1 min | 2.5 |
Pollution degree | 2 |
Električna življenjska doba | ≥ 2000 |
Mechanical Features
Mechanical Features | |
---|---|
Mechanical life | ≥ 2000 |
Fault current indicator | Yes |
Terminal protection degree | IP20 |
Ambient temperature (with daily average ≤35°C) | -25°C to 55°C |
Storage temperature | -40℃ to 70℃ |
Terminal connection type | Cable/Pin-type busbar |
Terminal size top/bottom for cable | 25-35 mm² 16-3/18-2 AWG |
Terminal size top/bottom for busbar | 10/16 mm² 18-8/18-5 AWG |
Navor za zategovanje | 2.5 N·m 22 in-lbs |
Montaža | On DIN rail EN 60715 (35mm) by means of fast clip device |
Connection | From top and bottom |
Standard | EN61008-1, IEC62955 |
VKL11 Type A EV 2P Residual Current Circuit Breaker (RCCB) Dimension
Understanding the VKL11 RCCB’s Unique Functionality
The VKL11 RCCB is not an ordinary residual current device. Specifically developed for Mode 3 EV charging applications, it provides specialized protection capabilities that standard RCCBs cannot offer. Let’s explore the distinctive features that make the VKL11 an integral component in modern electrical safety systems.
Type A Classification with Enhanced DC Protection
While conventional Type A RCCBs can detect both AC sinusoidal and pulsed DC residual currents, the VKL11 adds an additional layer of protection with its 6mA smooth DC detection capability. This enhanced functionality is crucial for EV charging systems, where DC leakage can occur due to the rectification components in charging equipment.
The VKL11 continuously monitors the electrical circuit for:
- AC sinusoidal residual currents (30mA – 50Hz)
- Pulsating DC residual currents
- Smooth DC residual currents (6mA)
This comprehensive monitoring ensures maximum safety for both users and equipment in EV charging environments, where the risk of DC leakage is significantly higher than in standard electrical installations.
Instantaneous Tripping Mechanism
Safety in electrical systems is measured in milliseconds. The VKL11 RCCB features an instantaneous tripping mechanism that activates without time-delay when a fault is detected. This rapid response is critical in preventing electrical accidents, particularly in EV charging scenarios where high currents are involved.
The tripping time under I∆n is ≤ 100ms, ensuring immediate circuit isolation when leakage currents exceed the threshold. This instantaneous protection is essential for safeguarding both users and valuable electrical equipment from potential damage.
Applications of the VKL11 Residual Current Circuit Breaker
The VKL11 RCCB is specifically designed for implementation in:
EV Charging Stations
As electric vehicles become increasingly prevalent, the need for safe and reliable charging infrastructure grows proportionally. The VKL11 RCCB is purpose-built for Mode 3 EV charging applications, offering specialized protection that standard RCCBs cannot provide.
In EV charging stations, the VKL11 protects against:
- AC leakage currents from charging equipment
- DC leakage from rectification components
- Transient currents during charging connection/disconnection
Residential EV Charging Points
Home-based EV charging installations require the same level of protection as commercial charging stations. The VKL11 RCCB provides peace of mind for homeowners, ensuring that their EV charging setup complies with the latest safety standards and regulations.
For residential applications, the VKL11 offers:
- Compact design for installation in standard consumer units
- Choice of sensitivity ratings to match specific installation requirements
- Reliable operation in typical residential temperature conditions
Commercial and Industrial EV Fleets
Businesses transitioning to electric vehicle fleets need robust charging infrastructure with comprehensive safety features. The VKL11 RCCB’s higher current ratings (up to 100A) and multiple pole configurations make it ideal for large-scale commercial charging installations.
In commercial settings, the VKL11 provides:
- Scalable protection for multiple charging points
- Compatibility with three-phase electrical systems (4P versions)
- Durability for continuous commercial operation
Installation and Dimensions
The VKL11 RCCB is designed for straightforward installation on standard 35mm DIN rails (EN 60715) using its integrated fast clip device. This compatibility ensures easy integration into new or existing electrical panels and consumer units.
Installation Dimensions
Outline and Installation Dimensions (mm) | |
---|---|
2P Version Width | 36 mm |
4P Version Width | 72 mm |
Višina | 85 mm |
Depth | 74 mm |
The compact design of the VKL11 optimizes panel space while maintaining full functionality and ease of access for maintenance and testing. Both top and bottom connections are available, providing flexibility for various installation configurations.
Compliance and Certification
The VKL11 RCCB is manufactured in strict accordance with international electrical standards, ensuring the highest level of safety and reliability. Key certifications include:
- IEC/EN 61008-1: International standard for residual current operated circuit-breakers without integral overcurrent protection
- IEC 62955: Specialized standard for residual direct current detecting equipment for EV charging applications
- UKCA/CE: Confirming compliance with relevant European and UK safety regulations
These certifications validate the VKL11’s performance and reliability, providing peace of mind for installers and end-users alike.
Maintenance and Testing
Like all residual current devices, the VKL11 RCCB requires periodic testing to ensure continued protection. The device features a built-in test button that simulates a fault condition, allowing users to verify that the tripping mechanism is functioning correctly.
Recommended testing frequency:
- Monthly: For residential installations
- Weekly: For commercial applications
- Daily: For critical safety installations
Regular testing ensures that the VKL11 RCCB remains in optimal working condition, providing continuous protection against electrical faults.
Conclusion: Why the VKL11 RCCB is Essential for EV Charging Safety
The VKL11 Residual Current Circuit Breaker represents a significant advancement in electrical safety technology, specifically tailored to the unique requirements of EV charging applications. With its comprehensive protection against both AC and DC residual currents, instantaneous tripping capability, and compliance with international standards, the VKL11 provides the peace of mind that comes from knowing your electrical installation is protected by industry-leading safety technology.
For electrical professionals, system integrators, and end-users looking to implement or upgrade EV charging infrastructure, the VKL11 RCCB offers the perfect balance of functionality, reliability, and ease of installation. By choosing the VKL11, you’re not just installing a circuit breaker – you’re investing in the future of electrical safety.
Contact VIOX today to learn more about the VKL11 RCCB and how it can enhance the safety and compliance of your electrical installations.