VIOX VSP1-C40PV/3(S) 1500V(D4) Priključni večpolni SPD

VIOX VSP1-C40PV/3(S) 1500V(D4) Pluggable Multi-Pole SPD offers robust surge protection for high-voltage photovoltaic systems up to 1500V DC. This Class I+II/Type 1+2 device safeguards (DC+) – PE and (DC-) – PE modes with 20kA nominal and 40kA maximum discharge current. Featuring high-energy MOV elements, it provides a voltage protection level of 5.6kV with < 25ns response time. The pluggable design ensures easy installation on 35mm DIN rails. Compliant with IEC 61643-31:2018 and EN 50539-11:2013+A1:2014, it includes IP20 protection, thermal safeguards, and optional remote contacts. This versatile multi-pole SPD combines reliability and performance for enhanced power system protection in demanding ultra-high-voltage DC and photovoltaic applications.

Pošljite svoje zahteve, ponudbo vam bomo posredovali v 12 urah

VIOX VSP1-C40PV/3(S) 1500V(D4) Priključni večpolni SPD

Pregled

The VIOX VSP1-C40PV/3(S) 1500V(D4) is a high-performance Pluggable Multi-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for (DC+) – PE and (DC-) – PE modes, making it an ideal solution for high-voltage photovoltaic systems and other DC applications requiring multi-pole protection up to 1500V.

Ključne lastnosti

  • Naprava razreda I, razreda II, tipa 1, tipa 2
  • Lokacija uporabe: Sub-distribucijske plošče
  • Način zaščite: (DC+) - PE, (DC-) - PE
  • Ocene prenapetosti: In = 20 kA (8/20 μs)
  • IEC/EN/UL Kategorija: Razred I+II / tip 1+2
  • Zaščitni elementi: Visokoenergijski MOV
  • Stanovanja: Priključna zasnova
  • Skladnost s predpisi: IEC 61643-31:2018, EN 50539-11:2013+A1:2014

Tehnične specifikacije

IEC Electrical 1500
Nazivna izmenična napetost 1500 V
Največja neprekinjena delovna napetost (DC) 1500 V
Nazivni tok praznjenja (8/20 μs) 20 kA
Največji tok praznjenja (8/20 μs) 40 kA
Impulzni tok praznjenja (10/350 μs) 6,25 kA
Raven zaščite pred napetostjo 5.6 kV
Odzivni čas < 25 ns
Varnostna varovalka (največ) 125 A gL / gG
Nazivni tok kratkega stika (AC) 25 kA / 50 kA

Mehanske in okoljske specifikacije

  • Območje delovne temperature: -40 °F do +158 °F [-40°C do +70°C]
  • Dovoljena delovna vlažnost: 5%...95%
  • Atmosferski tlak in nadmorska višina: 80k Pa ... 106k Pa / -500 m....2000 m
  • Navorni moment vijaka za priključek: 39,9 lbf.in [4,5 Nm]
  • Prečni prerez vodnika (max): 2 AWG (polni, pleteni) / 4 AWG (upogljivi)
  • 35 mm² (polni, pleteni) / 25 mm² (upogljivi)
  • Montaža: EN 60715
  • Stopnja zaščite: IP 20 (vgrajeno)
  • Material ohišja: Stopenj gašenja UL 94 V-0
  • Toplotna zaščita: Da:
  • Delovno stanje / indikacija napake: Zelena v redu / rdeča napaka

Dodatne funkcije

  • Daljinski stiki (RC): Izbirni
  • RC Preklopna zmogljivost: AC: 250 V / 0,5 A; DC: 250 V / 0,1 A; 125 V / 0,2 A; 75 V / 0,5 A
  • Prečni prerez vodnika RC (max): 16 AWG (polni) / 1,5 mm² (polni)

Notranja konfiguracija

Dimenzija

Diagram povezav

[Image placeholder for Connection Diagram]