VIOX FCT18-AgR Impulsforsinket tidsrelé med styresignal

The VIOX FCT18-AgR Pulse Delayed Timer Relay offers precise ON-delay (rising edge) timing for critical industrial applications. Features an extensive 0.1s-100 day range, <0.5% error, NPN/PNP control, 1 or 2 SPDT contacts, DIN rail mount, and versatile AC/DC 12-240V power. Robust and reliable.

Send oss dine krav, så gir vi deg et tilbud innen 12 timer

Introduction to the FCT18-AgR Pulse Delayed Relay

The VIOX FCT18-AgR is a high-performance pulse delayed relay designed for industrial automation systems that require precise timing control. With its ON-delay functionality and rising edge triggering mechanism, this device offers exceptional reliability for critical timing applications across various industries. The FCT18-AgR stands out in the market due to its wide time range settings, versatile power supply options, and robust anti-interference capabilities.

What is a Pulse Delayed Relay?

A pulse delayed relay is a specialized timing device that creates a controlled delay between when an input signal is received and when the output is activated. The FCT18-AgR specifically utilizes ON-delay functionality, meaning that when the trigger signal (Un) is applied, the relay output (R) activates only after a preset delay period has elapsed. This type of timing control is essential in sequential operations, process control, machine startup sequences, and safety applications.

VIOX FCT18-AgR Pulse Delayed Relay with Control Signal timing function

Key Features of the FCT18-AgR Pulse Delayed Relay

Eksepsjonell rekkevidde og nøyaktighet

The FCT18-AgR offers an impressive timing range from 0.1 seconds to 100 days, making it suitable for both rapid-response applications and long-term delay requirements. With ten distinct time setting ranges, including:

VIOX FCT18-AgR Pulse Delayed Relay with Control Signal time setting

  • 0,1-1 sekund
  • 1-10 sekunder
  • 0,1-1 minutt
  • 1-10 minutter
  • 0,1-1 time
  • 1-10 timer
  • 0,1-1 dag
  • 1-10 dager
  • 3-30 dager
  • 10-100 dager

This wide range enables precise control for virtually any industrial timing application. The time error is maintained at less than 0.5%, with a time deviation of just 0.1% and repeat accuracy of 0.5%, ensuring consistent and reliable operation in critical timing sequences.

Flexible Ratio Setting

One of the standout features of the FCT18-AgR is its adjustable ratio setting, which allows fine-tuning of the timing duration within each time range. The ratio can be set from 10% to 100% in 5% increments (10%, 15%, 20%, etc.), providing exceptional precision for your specific application requirements.

VIOX FCT18-AgR Pulse Delayed Relay with Control Signal ratio setting

Allsidige strømforsyningsalternativer

The FCT18-AgR supports a wide power supply range from 12V to 240V AC/DC, making it compatible with virtually any industrial power system. This versatility eliminates the need for additional power conversion components, simplifying installation and reducing overall system complexity. The device features a generous voltage tolerance of -15% to +10%, ensuring stable operation even in environments with fluctuating power conditions.

Robust design for industrielle miljøer

Designed specifically for industrial applications, the FCT18-AgR features:

  • Strong anti-interference capability, ensuring reliable operation even in electrically noisy environments
  • Operating temperature range from -20°C to +85°C (-4°F to +185°F)
  • Temperaturkoeffisient på 0,05%/°C ved 20°C (0,05%/°F ved 68°F)
  • IP20-beskyttelsesgrad
  • DIN rail mounting capability compliant with EN/IEC 60715
  • Compact dimensions of 90mm × 18mm × 64mm (3.54″ × 0.71″ × 2.52″)
  • Low power consumption of just 2.0W
  • Vurdering av forurensningsnivå 2
  • Compliance with GB/T 14048.5, IEC60947-5-1, and EN6812-1 standards

Tydelige visuelle indikatorer

The FCT18-AgR features intuitive LED indicators for operational status monitoring:

  • Grønn LED for indikering av strømtilførsel
  • Rød LED for indikasjon av reléstatus

These visual cues allow for quick troubleshooting and status verification at a glance.

How the FCT18-AgR ON-Delay Function Works

The FCT18-AgR operates on a rising edge triggering mechanism, where the timing sequence begins when the input signal (Un) transitions from low to high. During the preset delay period, the signal processing occurs, and the output remains inactive. Once the delay time has elapsed, the relay output (R) activates.

The timing function diagram illustrates this operation:

  1. When the input signal (Un) is applied, the delay processing begins
  2. The signal (S) is considered invalid during the delay processing period
  3. After the preset time (T) elapses, the relay output (R) activates
  4. This process repeats for each triggering event

A critical advantage of the FCT18-AgR is that the delay processing is not affected by the signal (S), ensuring consistent timing regardless of signal fluctuations.

Veiledning for valg av modell

The FCT18-AgR series offers various configurations to meet specific application requirements. The model designation follows this format:

FCT18-AgR X Y Z

Hvor?

  1. Funksjon: AgR = ON-delay
  2. Type utgang:
    • 1 = 1 CO contact (1*SPDT, rated 16A)
    • 2 = 2 CO contacts (2*SPDT, rated 16A)
  3. Forsyningsspenning:
    • A = AC230V
    • D = DC24V
    • W = AC/DC 12-240V
  4. Kontrollsignal:
    • N = NPN
    • P = PNP

Tilgjengelige modeller

  • FCT18-AgR1: Features 1 CO contact configuration
  • FCT18-AgR2: Features 2 CO contacts configuration

Tekniske spesifikasjoner

Input Terminal Specifications

Parameter Verdi
Spenningsområde VEKSELSTRØM 230V / LIKESTRØM 24V / VEKSELSTRØM/LIKESTRØM 12-240V
Strømforbruk AC 3,5VA/ DC 2,0W
Spenningstoleranse -15% ~ +10%
Forsyningsindikasjon Grønn LED
Reléindikasjon Rød LED

Tidsspesifikasjoner

Parameter Verdi
Tidsintervaller 0,1s-100 dager
Tidsinnstilling Knapp
Tidsavvik 0.1%
Gjentagelsesnøyaktighet 0.5%
Temperaturkoeffisient 0.05%/°C, at ±20°C (0.05%/°F, at ±68°F)

Utgangsspesifikasjoner

Parameter FCT18-AgR1 FCT18-AgR2
Utgangskontakt 1*SPDT 2*SPDT
Nominell strøm 1*16A 2*16A

Miljømessige og fysiske spesifikasjoner

Parameter Verdi
Mekanisk levetid 1*10⁷
Elektrisk levetid 1*10⁵
Omgivelsestemperatur -20 ... +60 °C / -40 ... +85 °C
Montering DIN-skinne EN/IEC 60715
IP-klassifisering IP20
Strippingens lengde 7 mm (0,28 tommer)
Installert høyde ≤2200m
Forurensningsnivå 2
Maks kabelstørrelse AWG13-20 0,4N-m
Dimensjon 90 mm * 18 mm * 64 mm
Vekt ca. 90 g
Standarder GB/T 14048.5, IEC60947-5-1, EN6812-1

Instruksjoner for kabling

The FCT18-AgR offers flexible wiring options for both NPN and PNP control signals:

VIOX FCT18-AgR Pulse Delayed Relay with Control Signal wiring

NPN Wiring Configuration

  • Un connects to the power source
  • S connects to the control signal
  • Outputs are available at terminals 11, 12, 14, 21, 22, and 24

PNP Wiring Configuration

  • Un connects to the power source
  • S connects to the control signal
  • Outputs are available at terminals 11, 12, 14, 21, 22, and 24

The clearly labeled terminals (A1, A2, S, etc.) and the wiring diagrams printed on the product make installation straightforward and error-free.

Dimensjon

VIOX FCT18-AgR Pulse Delayed Relay with Control Signal dimension

Applications of the FCT18-AgR Pulse Delayed Relay

The FCT18-AgR is exceptionally versatile and finds applications across numerous industries:

Automatisering av produksjon

  • Sequential machine startup to prevent power surges
  • Controlled process timing for assembly lines
  • Conveyor system synchronization
  • Automated testing sequences

HVAC-systemer

  • Delayed fan startup after heating element activation
  • Timed ventilation cycles
  • Compressor protection with minimum off-time delay

Pump and Motor Control

  • Water pump cycling with precise intervals
  • Motor soft-start timing control
  • Pump alternation in multi-pump systems

Belysningskontroll

  • Staircase lighting timers
  • Sequential lighting activation for large spaces
  • Energy-saving automatic shutoff timing

Sikkerhetssystemer

  • Emergency shutdown sequences
  • Alarm delay verification to prevent false triggers
  • Evacuation timing sequences

Energistyring

  • Load shedding with timed sequences
  • Peak demand management
  • Sekvensering av generatoroppstart

Fordeler i forhold til konkurrerende produkter

The FCT18-AgR offers several distinct advantages compared to similar products on the market:

  1. Exceptionally Wide Time Range: The 0.1s to 100-day range exceeds most competitors who typically offer more limited ranges.
  2. Overlegen nøyaktighet: With time error less than 0.5% and repeat accuracy of 0.5%, the FCT18-AgR provides more consistent timing than many alternatives.
  3. Universell strømforsyning: The wide 12-240V AC/DC supply range eliminates the need for specific voltage models, reducing inventory requirements.
  4. Kompakt design: At just 18mm wide, the FCT18-AgR occupies minimal DIN rail space while delivering high-performance capabilities.
  5. Intuitive Controls: The combination of ratio setting dials and time range selection makes configuration straightforward even for complex timing requirements.
  6. Strong Anti-Interference: Specifically designed to resist electrical noise, making it suitable for harsh industrial environments where less robust relays might fail.

Veiledning for installasjon og oppsett

Installing the FCT18-AgR is straightforward:

  1. Mount the relay on a standard 35mm DIN rail according to EN/IEC 60715.
  2. Connect the power supply to terminals A1 and A2, ensuring the voltage is within the specified range.
  3. Connect the control signal to terminal S, following either the NPN or PNP wiring diagram as appropriate for your control system.
  4. Connect the output loads to the appropriate terminals (11, 12, 14 for single contact models; adding 21, 22, 24 for dual contact models).
  5. Set the desired time range using the time setting rotary switch. Select from the ten available ranges (0.1-1s, 1-10s, etc.).
  6. Adjust the ratio setting from 10% to 100% to fine-tune the exact timing duration within the selected range.
  7. Verify operation by checking the LED indicators: green for power and red for relay activation.

Vedlikehold og feilsøking

The FCT18-AgR is designed for minimal maintenance, but here are some troubleshooting tips:

  • Reléet aktiveres ikke: Check power supply connections and verify the green LED is lit.
  • Timing seems inaccurate: Verify the time range and ratio settings are correctly positioned.
  • Intermitterende drift: Check for electromagnetic interference sources nearby and ensure adequate spacing between the relay and high-current devices.

Konklusjon

The VIOX FCT18-AgR pulse delayed relay represents an excellent choice for industrial timing control applications where precision, reliability, and versatility are essential. With its extensive timing ranges, high accuracy, flexible power supply options, and robust construction, this relay delivers consistent performance in demanding environments. The intuitive controls and clear status indicators make it easy to configure and monitor, while the compact DIN rail mount design conserves valuable panel space.

Whether you need precise timing control for manufacturing processes, HVAC systems, pump control, lighting, or safety applications, the FCT18-AgR provides the functionality and reliability needed for critical industrial systems. Its compliance with international standards ensures it meets the regulatory requirements for industrial control components.

For reliable pulse delay control that offers exceptional versatility and precision, the VIOX FCT18-AgR stands as a premier solution in the industrial timing relay market.

Relaterte produkter

Be om tilbud nå

Be om tilbud nå