ASTP-Y Tidsrelé
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Send oss dine krav, så gir vi deg et tilbud innen 12 timer
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
VIOX ASTP-Y Analog Timer
Oversikt
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Viktige funksjoner
- Nøyaktig tidskontroll: Justerbart tidsområde fra 0 til 60 sekunder med en analog skive.
- Pålitelig drift: Veksler relékontakter etter innstilt tid og opprettholder posisjonen.
- Doble reléutganger: To reléutganger med en maksimal belastning på 5A hver.
- Enkel installasjon: Inkluderer PF083A-sokkel for DIN-skinnemontering.
- Visuelle indikatorer: Arbeidsindikator på frontpanelet for enkel overvåking.
- Slitesterk konstruksjon: Designet for langvarig ytelse med høy mekanisk og elektrisk levetid.
- Bredt spenningsområde: Drives på 230 VAC med en toleranse på +/-10%.
Spesifikasjoner
CLASSIFICATION | TIMER | TIMER | ||||||
MODELL | ASTP-N | ASTP-Y | AH2-N | AH2-Y | ||||
APPEARANCE | ||||||||
DIMENSIONS | 61H×49W×70D | 88H×58W×68D | 61H×49W×70D | 88H×58W×68D | ||||
MOUNTING & SOCKET |
SURFACE(-N) | PF083A(E) PS-08 | PF083A(E) PS-08 | |||||
FLUSH(-Y) | US-08 P3G-08 | US-08 P3G-08 | ||||||
FULL TIMING RANGE | SEC:1,3,6,10,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
SEC:1,3,6,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
||||||
RATED VOLTAGE | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | ||||||
INDICATOR OPERATING | Time Operating | ON-UP Two indicator Lamp ON-UP | ||||||
CONTACT | MODELL | ASTP-N1/ ASTP-Y1 | ASTP-N2/ ASTP-Y2 | ASTP-N/ ASTP-Y | AH2-N1/ AH2-Y1 | AH2-N2/ AH2-Y2 | AH2-N/ AH2-Y | |
TIME LIMIT 1C | 5A | 5A | 5A | 5A | ||||
TIME LIMIT 2C | 5A | 5A | ||||||
INSTANTANEOUS 1C | 5A | 5A | ||||||
LIFE | MECHANICAL | 5×106 ganger | 5×106 ganger | |||||
ELECTRICAL | 105 ganger | 105 ganger | ||||||
ACCURACY | REPEAT ERROR | ±1% max | ±1% max | |||||
SETTING ERROR | ±10% max | ±10% max | ||||||
VOLTAGE ERROR | ±1% max | ±1% max | ||||||
TEMP. ERROR | ±2% max | ±2% max | ||||||
RESET TIME | 0.1 sec max | 0.1 sec max | ||||||
CONSUMED POWER | 2VA | 3VA | ||||||
AMBIENT TEMPERATURE | -10℃~+55℃ | -10℃~+55℃ | ||||||
AMBIENT HUMIDITY | 48~85%RH | 48~85%RH | ||||||
WEIGHT | 220 g | 220 g | ||||||
CONNECTION DIAGRAMS & TIMING CHART | 39A | 39B | 39C | 39D | 39E | 39F |
Bruksområder
VIOX ASTP-Y analog timer er ideell for en rekke bruksområder innen industriell automasjon og mekaniske enheter. Den er egnet for bruk i kontrollpaneler, maskiner og andre systemer som krever presis tidsstyring. Timerens robuste design og pålitelige ytelse gjør den til et utmerket valg for både kommersielle og industrielle miljøer.
Tekniske data
- Strømforsyning: 230 VAC +/-10%
- Produksjon: Relé
- Maks. belastning: 5A
- Tidsrom: 0–60 sekunder
- Dimensjoner: 40×50 mm
- Montering: DIN-skinne, i tabellen
- Oppløsning: Analog urskive
- Beskyttelsesgrad: IP40
- Mekanisk levetid: 5×106 ganger
- Elektrisk levetid: 105 ganger
- Nøyaktighet: Gjentakende feil: ±1% maks., Innstillingsfeil: ±10% maks., Spenningsfeil: ±1% maks., Temp.feil: ±2% maks.
- Tilbakestillingstid: 0,1 sek. Maks.
- Forbrukt strøm: 2VA
- Omgivelsestemperatur: -10℃ til +55℃
- Luftfuktighet i omgivelsene: 48% til 85% høyre
- Vekt: 220 g
Tilkoblingsskjema
VIOX ASTP-Y analog timer har et enkelt koblingsskjema for enkel installasjon. Enheten begynner å telle den innstilte tiden når strømforsyningsspenningen tilføres, og kobler deretter relékontaktene og forblir i denne posisjonen. Relé A1 fungerer i henhold til den innstilte tiden på panelet, mens relé A2 fungerer i henhold til timerens strømforsyning.
Utgangsmoduser
Når strømforsyningsspenningen tilføres, begynner enheten å telle den innstilte tiden og kobler deretter relékontaktene, samtidig som den opprettholder denne posisjonen. Relé A1 fungerer i henhold til den innstilte tiden på panelet, og relé A2 fungerer i henhold til timerens strømforsyning. Nedenfor er driftsdiagrammet: