VKL11B 2P Үлдэгдэл гүйдэлтэй ажилладаг таслуур (RCCB)
The VIOX VKL11B 2P Type B Residual Current Circuit Breaker (RCCB) offers comprehensive electrical safety, detecting AC, pulsed DC, болон smooth DC residual currents (up to 1kHz). This 2-pole RCCB is essential for applications like EV chargers, PV systems, and industrial equipment, providing superior protection where standard RCCBs fall short. Complies with IEC/EN 62423 and IEC/EN 61008-1.
Шаардлагаа илгээнэ үү, бид танд 12 цагийн дотор үнийн санал өгөх болно
- УТАС:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Introduction to VKL11B/B+ Residual Current Circuit Breakers
The VIOX VKL11B series represents our advanced line of universal residual current circuit breakers (RCCBs), engineered for maximum electrical safety in both domestic and industrial applications. Available in both Type B and Type B+ variants, these devices offer superior protection against various forms of residual current, including smooth DC currents that conventional RCDs cannot detect.
Built with electronic technology for precise residual current measurement, the VKL11B RCCB delivers enhanced reliability with reduced unwanted tripping and immunity to magnetization issues that commonly affect standard mechanical devices.
What Makes the VKL11B RCCB Series Different?
The VKL11B RCCB differentiates itself through its comprehensive detection capabilities across multiple residual current types:
- Sinusoidal AC residual currents
- Pulsed DC residual currents
- Alternating residual sinusoidal currents up to 1000Hz
- Pulsating direct residual currents
- Smooth direct residual currents (a key advantage over standard RCDs)
This versatility makes the VKL11B RCCB suitable for modern electrical systems where conventional protection devices may not provide adequate safety coverage.
VKL11B vs VKL11B+: Understanding the Difference
While both variants share the same compact design and core functionality, the key differences lie in their frequency detection capabilities and tripping characteristics:
Онцлог | VKL11B (Type B) | VKL11B+ (Type B+) |
---|---|---|
Frequency detection limit | Up to 1 kHz | Up to 20 kHz |
Maximum tripping current | 420mA | 420mA |
Үйл ажиллагаа | Voltage independent | Voltage dependent |
Tripping sensitivity | Standard Type B protection | Enhanced frequency response |
Техникийн үндсэн параметрүүд
Цахилгаан техникийн үзүүлэлтүүд
Параметр | B төрөл | Type B+ |
---|---|---|
дагуу дизайн хийх | IEC/EN 62423, IEC/EN 61008-1, OVE E8601, VDE 0664-400 | |
Нэрлэсэн хүчдэл Un | 2P: 230/240V хувьсах гүйдэл 4P: 400/415V хувьсах гүйдэл |
2P: 230/240V хувьсах гүйдэл 4P: 400/415V хувьсах гүйдэл |
Нэрлэсэн давтамж fn | 50/60 Гц | |
Үйл ажиллагааны горим | A-type functionality: voltage independent | B and B-type functionality: voltage dependent |
Operation voltage electronic | 50 – 264V AC | |
Хүчдэлийн хүрээний туршилтын хэлхээ | 2P: 184 – 264V хувьсах гүйдэл 4P: 184 – 440V хувьсах гүйдэл |
2P: 184 – 264V хувьсах гүйдэл 4P: 184 – 440V хувьсах гүйдэл |
Нэрлэсэн гүйдэл In | 16А, 25А, 32А, 40А, 63А, 80А, 100А | |
Rated operating current I∆n | 30mA, 100mA, 300mA, 500mA | 30мА, 100мА, 300мА |
Мэдрэмж | For AC, pulsed and smooth direct currents 1 кГц хүртэл өндөр давтамжтай |
For AC, pulsed and smooth direct currents High frequency up to 20kHz |
Тусгаарлагчийн нэрлэсэн хүчдэл Ui | 500 В | |
Нэрлэсэн импульсийг тэсвэрлэх хүчдэл Uimp | 4 кВ (1.2/50μс) | |
Нэрлэсэн нөхцөлт богино залгааны гүйдэл Inc | 10 кА | |
Нэрлэсэн хийх ба эвдэх чадвар Im | 1500 А | |
Оргил гүйдлийг тэсвэрлэх | 3 кА (8/20 мкс) хүчдэлийн гүйдлийн баталгаа | 5 kA (8/20 μs) surge current proof for type S |
Механик үзүүлэлтүүд
Параметр | Тодорхойлолт |
---|---|
Хамгаалалтын зэрэг | IP20 |
Дээд ба доод терминалууд | Open mounted / lift terminals |
Терминалын хүчин чадал | 1-25 мм² |
Терминал момент | 2 - 2.5 Нм |
Автобусны зузаан | 0.8 - 2 мм |
Ашиглалтын температур | -25°C ... +55°C |
Storage and transport temperature | -40°C ... +70°C |
Цаг уурын нөхцөлд тэсвэртэй байдал | IEC/EN 61008 |
Холбоо барих байршлын үзүүлэлт | Mechanical red / green |
Нийлүүлэлтийн боломж | Top or bottom |
Суурилуулах байрлал | Any |
Цахилгаан тусгаарлагч | ≥ 4 mm contact space |
Maximum back-up fuse In ≤ 16-100A | Богино холболт ба хэт ачааллаас хамгаалах 100 А гГ/гЛ |
Тэвчээр (үйл ажиллагааны мөчлөг) | Electrical components: ≥ 2000 Mechanical components: ≥ 4000 |
VKL11B 2P (RCCB) Dimension
VKL11B 2P RCCB холболтын диаграмм
Tripping Characteristics and Protection Features
The VKL11B RCCB offers differentiated protection levels based on the residual current magnitude:
30 мА
Provides additional protection against direct contact with live parts. This sensitivity level is essential for circuits accessible to the general public or untrained personnel.
100мА
Co-ordinated with the earth system (when earth resistance I∆n < 50Ω), providing effective protection against indirect contacts.
300 мА
Designed for protection against indirect contacts and as fire hazard prevention in high-risk areas.
Tripping Time Options
- Шуурхай: Ensures immediate tripping without time delay
- Short time delay: Brief predetermined delay before tripping
- Selective (time delay): Longer delay for coordination with other protection devices
Applications: Where to Use VKL11B RCCBs
The VKL11B is specifically designed for applications vulnerable to smooth DC residual currents, making it ideal for:
- Frequency converters with three-phase connection
- Medical equipment including X-ray machines and CT scanners
- Photovoltaic installations and UPS systems
- EV charging stations and connection points
- Elevator controllers
- Pipeline trace heating systems
- Laboratory test setups
- Construction sites (compliant with BGI 608 regulations)
- Battery-powered forklift truck charging stations
- Crane electrical systems
- Industrial mixing plants with connected loads
- Variable-speed machine tools (milling machines, grinding equipment, lathes)
Суурилуулалт ба хэмжээс
The VKL11B RCCB features a compact design with clearly defined dimensions for easy installation in electrical panels:
- Width: 2-pole models – 35.8mm; 4-pole models – 71.7mm
- Height: 81.5mm
- Depth: 74mm
The device can be mounted in any orientation and accepts supply connections from either top or bottom terminals. Installation should follow standard DIN rail mounting procedures, with proper terminal tightening to the specified torque values.
Certifications and Compliance
The VKL11B RCCB series is manufactured in accordance with the following standards:
- IEC/EN 62423
- IEC/EN 61008-1
- OVE E8601
- VDE 0664-400
The devices carry UKCA and CE certification marks, confirming their compliance with relevant European safety standards and regulations.
Key Advantages of VKL11B RCCB
- Сайжруулсан хамгаалалт: Detects and responds to all types of residual current, including smooth DC current that standard RCDs cannot detect
- Electronic Technology: More accurate residual current measurement compared to mechanical devices
- Reduced Unwanted Tripping: Advanced detection algorithms minimize nuisance trips
- No Magnetization Issues: Unlike mechanical RCDs, the electronic tripping unit doesn’t suffer from magnetization problems
- Олон талын хэрэглээ: Suitable for both domestic and industrial environments
- Давтамжийн хүрээ: Type B+ variant offers protection up to 20kHz, ideal for high-frequency applications
- Компакт дизайн: Space-saving dimensions for electrical panel installation
- Clear Status Indication: Mechanical red/green indicator shows contact position
- Олон тооны одоогийн үнэлгээ: Available in various rated currents from 16A to 100A
- Different Sensitivity Options: 30mA, 100mA, 300mA, and 500mA variants for tailored protection
When to Choose VKL11B+ Over Standard VKL11B
Select the VKL11B+ (Type B+) variant for:
- Applications with high-frequency equipment operating up to 20kHz
- Systems requiring enhanced surge current tolerance (5kA vs 3kA)
- Installations where voltage-dependent functionality is preferred
- Applications with specialized equipment generating frequencies above 1kHz
The standard VKL11B (Type B) is suitable for most general applications where frequencies remain below 1kHz and basic protection against smooth DC residual currents is required.
Selection Guide: Choosing the Right VKL11B RCCB
To select the appropriate VKL11B RCCB for your application, consider the following factors:
- Rated Current (In): Choose based on the maximum load current of the protected circuit
- Sensitivity (I∆n): Select 30mA for personnel protection, 100-300mA for fire protection or equipment safety
- Польшууд: 2-pole for single-phase systems, 4-pole for three-phase systems
- Төрөл: B for standard applications, B+ for high-frequency applications
- Tripping Time: Instantaneous for general protection, selective (time-delayed) for coordination with other protective devices
Technical FAQ
What is the difference between Type A, Type B, and Type B+ RCCBs?
Type A RCCBs detect AC sinusoidal and pulsating DC residual currents. Type B RCCBs add detection of smooth DC residual currents up to 1kHz. Type B+ extends frequency detection up to 20kHz for specialized applications.
Can I replace a standard RCCB with a VKL11B RCCB?
Yes, the VKL11B can replace standard RCCBs and will provide enhanced protection. However, note that Type B devices are more specific to certain applications and may be more costly than Type A or AC types for general use.
Why might I need a Type B RCCB instead of a standard Type A?
Type B RCCBs are essential when equipment may generate smooth DC residual currents, such as with frequency converters, UPS systems, EV chargers, and medical equipment. Standard Type A RCCBs cannot detect these currents, creating a potential safety gap.
What is the maximum back-up protection required?
The VKL11B series requires a maximum back-up fuse of 100A gG/gL for short circuit and overload protection.
Can the VKL11B RCCB be installed in outdoor applications?
The VKL11B has an IP20 protection rating, meaning it must be installed in a suitable enclosure if used in outdoor or harsh environments.
Дүгнэлт
The VIOX VKL11B series of residual current circuit breakers represents the pinnacle of electrical protection technology, offering comprehensive safety for modern electrical systems. With their ability to detect and respond to all types of residual currents, including smooth DC currents that conventional devices cannot detect, these RCCBs provide essential protection for specialized applications in both industrial and domestic settings.
The differentiation between Type B and Type B+ variants allows for precise selection based on specific application requirements, ensuring optimum protection across various electrical systems. When selecting an RCCB for applications involving frequency converters, medical equipment, EV charging stations, or other technology that may generate DC residual currents, the VKL11B RCCB provides the reliable protection necessary for both equipment safety and personnel protection.