VIOX FCT18-Ata нийлбэр хяналтын дохио бүхий импульсийн саатсан таймер реле
The VIOX FCT18-Ata Pulse Delayed Timer Relay offers precise ON-delay timing (0.1s-100 days) with summation of NPN/PNP control signal pulses. Features <0.5% error, 1 or 2 SPDT contacts, DIN rail mount, and supports AC/DC 12-240V, Ideal for automation and process control requiring pulse accumulation.
Шаардлагаа илгээнэ үү, бид танд 12 цагийн дотор үнийн санал өгөх болно
- УТАС:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Бүтээгдэхүүний тойм
The VIOX FCT18-Ata is an advanced pulse delayed timer relay designed for precise timing control in industrial automation, process control, and electrical systems. With its ON-delay function and summation control signal capability, this timer relay provides exceptional accuracy and reliability for applications requiring precise timing sequences. The FCT18-Ata stands out with its wide time range settings from 0.1 seconds to 100 days, broad power supply compatibility, and industry-leading accuracy.
Гол онцлог, ашиг тус
- Versatile Timing Range: Exceptional flexibility with timing ranges from 0.1 seconds to 100 days, suitable for both ultra-short and extended timing applications
- ON-Delay Function with Summation Control: Advanced timing function that sums multiple input pulses (t1 + t2 + … + tx) for precise process control
- Эрчим хүчний хангамжийн өргөн хүрээ: Compatible with 12 to 240 VAC/DC power supplies, making it versatile for various global installation requirements
- Өндөр нарийвчлал: Time error less than 0.5% and time deviation of only 0.1%, ensuring reliable and consistent operation
- Хөндлөнгийн эсрэг хүчтэй чадвар: Built to withstand electromagnetic interference in industrial environments
- Хялбар тохиргоо: Intuitive configuration with convenient wiring diagrams printed on the device
- DIN төмөр замын бэхэлгээ: Standard DIN rail EN/IEC 60715 mounting for easy installation in control cabinets
- LED Status Indicators: Green LED for power supply indication and red LED for relay status
- IP20 Protection: Suitable for indoor industrial environments
- Олон улсын нийцэл: Meets GB/T 14048.5, IEC60947-5-1, EN6812-1 standards
Understanding the FCT18-Ata Timing Function
The FCT18-Ata features an ON-delay timing function with pulse summation capability, making it ideal for applications requiring cumulative timing:
Ata: ON-delay with Summation Control
When the control input (S) receives pulses, the timer accumulates the duration of all valid pulses. The timing diagram illustrates how multiple input signals (t1, t2, t3, …, tx) are summed together, with the output relay (R) activating when the total accumulated time (T = t1 + t2 + … + tx) is reached. This feature is particularly valuable in processes where multiple events need to trigger a response based on their cumulative duration.
Time Setting Options
The FCT18-Ata offers unparalleled flexibility with its comprehensive time range settings:
Хүрээ | Тодорхойлолт | Ердийн програмууд |
---|---|---|
0.1-1 сек | Ultra-short timing range in tenths of seconds | High-speed manufacturing, rapid response safety systems |
1-10 секунд | Short timing range in seconds | Process control, conveyor systems, light sequencing |
0.1-1м | Timing in tenths of minutes | Material handling, basic industrial processes |
1-10 м | Timing in minutes | Machine cycles, cooling systems, heating processes |
0.1-1 цаг | Timing in tenths of hours | Extended processing, environmental control systems |
1-10 цаг | Timing in hours | Long-duration industrial processes, extended cycles |
0.1-1 өдөр | Timing in tenths of days | Daily manufacturing cycles, daily maintenance |
1-10 хоног | Timing in days | Extended industrial processes, multi-day cycles |
3-30 хоног | Extended timing in months | Long-term monitoring, scheduled maintenance |
10-100 хоног | Maximum duration timing | Seasonal operations, long-term processing |
Ratio Setting Options
Fine-tune your timing precision with 18 ratio settings from 10% to 100%, allowing precise calibration of the timing function:
Харьцааны тохиргоо | Өргөдөл |
---|---|
10%, 15%, 20%, 25% | Low-range precision timing for delicate processes |
30%, 35%, 40%, 45%, 50%, 55% | Mid-range timing for standard industrial applications |
60%, 65%, 70%, 75%, 80%, 85%, 90%, 95%, 100% | High-range timing for extended duration processes |
Утасны сонголтууд
The FCT18-Ata supports both NPN and PNP control signal configurations, offering versatile integration options:
- NPN тохиргоо: Suitable for sinking current applications
- PNP тохиргоо: Suitable for sourcing current applications
The relay features dedicated terminals for power supply (Un), control signal (S), and output contacts (OA1, OA2).
Хэмжээ
Загвар сонгох гарын авлага
The FCT18-Ata is available in multiple configurations, following the model code system: FCT18-Ata1_W_N
Албан тушаал | Код | Тодорхойлолт |
---|---|---|
1. Үйл ажиллагаа | Ata | ON-delay with summation control |
2. Гаралтын төрөл | 1 | 1CO contact (1 changeover contact) |
2 | 2CO contacts (2 changeover contacts) | |
3. Нийлүүлэлтийн хүчдэл | А | AC 230V |
Д | DC 24V | |
В | Хувьсах / DC 12-240 В | |
4. Хяналтын дохио | Н | NPN |
P | PNP |
Техникийн үзүүлэлтүүд
Параметр | FCT18-Ata1 | FCT18-Ata2 |
---|---|---|
Оролтын терминал | А1-А2 | А1-А2 |
Хүчдэлийн хүрээ | Хувьсах гүйдлийн 230V / DC 24V / хувьсах гүйдэл / DC 12-240V | |
Эрчим хүчний хэрэглээ | Хувьсах гүйдэл 3.5VA/ DC 2.0W | |
Хүчдэлийн хүлцэл | -15% ~ +10% | |
Нийлүүлэлтийн заалт | Ногоон LED | |
Релений заалт | Улаан LED | |
Цагийн хүрээ | 0.1с-100 хоног | |
Цагийн тохиргоо | Товчлуур | |
Цагийн хазайлт | 0.1% | |
Нарийвчлалыг давтах | 0.5% | |
Температурын коэффициент | 0.05%/°C, =20°C (0.05%/°F, =68°F) | |
Гаралтын контакт | 1 * SPDT | 2 * SPDT |
Нэрлэсэн гүйдэл | 1*16А | 2*16А |
Механик амьдрал | 1*10⁷ | |
Цахилгааны амьдрал | 1*10⁵ | |
Орчны температур | -20 … +60 °C / -40 … +85 °C | |
Суурилуулалт | DIN төмөр зам EN/IEC 60715 | |
IP үнэлгээ | IP20 | |
Хөрс тайрах урт | 7мм (0.28 инч) | |
Суулгасан өндөр | ≤2200м | |
Бохирдлын түвшин | 2 | |
Кабелийн дээд хэмжээ | AWG13-20 0.4Н·м | |
Хэмжээ | 90мм*18мм*64мм | |
Жин | ойролцоогоор 90 гр | |
Стандартууд | GB/T 14048.5, IEC60947-5-1, EN6812-1 |
Applications of FCT18-Ata Pulse Delayed Timer Relay
The FCT18-Ata is exceptionally versatile and can be utilized in numerous industrial and commercial applications:
Аж үйлдвэрийн автоматжуулалт
- Sequential Process Control: Time-based activation of multiple process steps in manufacturing lines
- Conveyor Systems: Controlling start/stop timing and synchronization between different conveyor sections
- Packaging Machinery: Precise timing for folding, sealing, and cutting operations
- Material Handling Equipment: Controlled movement sequences with precise timing intervals
Барилгын автоматжуулалт
- HVAC системүүд: Timed control of heating, ventilation, and air conditioning cycles
- Гэрэлтүүлгийн хяналт: Advanced timing for public area lighting, including stairwells and corridors
- Хамгаалалтын системүүд: Timed delay for access control and alarm integration
- Pump Control: Timed operation of water pumps and irrigation systems
Эрчим хүчний менежмент
- Generator Systems: Controlled startup and shutdown sequences
- Эрчим хүчний хуваарилалт: Timed switching between power sources
- Load Shedding: Sequential disconnection of non-critical loads
- Energy Conservation: Timed operation of equipment to minimize energy consumption
Process Industries
- Chemical Processing: Precise timing for mixing and reaction processes
- Food & Beverage: Control of processing times for consistent product quality
- Pharmaceutical: Precise timing for sterilization and production processes
- Усны эмчилгээ: Controlled cycle times for filtration and treatment processes
Суулгах ба тохируулах гарын авлага
Installing and configuring the FCT18-Ata is straightforward:
Суулгах алхамууд
- Mount the relay on a standard DIN rail in your control cabinet
- Цахилгаан хангамжийг A1 ба A2 терминалуудад холбоно
- Wire the control signal (S) according to your NPN or PNP configuration
- Connect output devices to the appropriate output terminals (11-14, 21-24 for dual output model)
- Set the desired time range using the rotary selector
- Fine-tune the timing ratio using the percentage dial
- Apply power and verify operation with the LED indicators
Wiring Precautions
- Ensure proper voltage levels according to specifications
- Use wire sizes not exceeding AWG13-20
- Maintain proper stripping length of 7mm (0.28in)
- Follow the correct NPN or PNP wiring diagram as indicated on the product
- Ensure environmental conditions meet the IP20 rating requirements
Troubleshooting Guide
Common issues and solutions for the FCT18-Ata timer relay:
Асуудал | Possible Cause | Шийдэл |
---|---|---|
Relay does not activate | No power supply | Check power connections and voltage level |
Green LED not illuminated | Power supply issue | Verify power supply is within -15% to +10% tolerance |
Timing function not working | Incorrect signal connection | Verify correct NPN/PNP wiring configuration |
Тогтворгүй цаг хугацаа | Environmental interference | Ensure proper installation away from high EMI sources |
Relay activates too early/late | Incorrect time/ratio setting | Adjust time range and ratio settings according to requirements |
Invalid signal detection | Signal outside specification | Verify control signal meets the device requirements |
Why Choose VIOX FCT18-Ata Pulse Delayed Timer Relay?
The FCT18-Ata stands out from competitors with its exceptional combination of features and benefits:
- Unmatched Versatility: With time ranges from 0.1 seconds to 100 days, this single device can replace multiple specialized timers
- Superior Accuracy: Time error less than 0.5% and time deviation of only 0.1% ensures precise and reliable operation
- Universal Compatibility: Wide power supply range (12-240 VAC/DC) makes it suitable for global applications
- Industrial Robustness: Operating temperature range of -20°C to +60°C with strong anti-interference capability ensures reliable performance in harsh environments
- Сансрын хэмнэлттэй дизайн: Compact dimensions (90mm*18mm*64mm) allow for efficient use of control cabinet space
- Long Service Life: Mechanical durability of 10 million operations and electrical durability of 100,000 operations at rated load
- Clear Visual Indication: Dual LED indicators for power supply (green) and relay status (red)
- Олон улсын нийцэл: Meets relevant global standards for industrial control equipment
Дүгнэлт
The VIOX FCT18-Ata pulse delayed timer relay with summation control signal represents the pinnacle of timing relay technology. Its exceptional versatility, precision, and reliability make it the ideal choice for industrial automation, building management, energy control, and process industries. With its comprehensive range of timing options, dual contact configurations, and universal power supply compatibility, the FCT18-Ata provides a single-device solution for virtually any timing control application.
By choosing the FCT18-Ata, you’re investing in a product engineered to deliver consistent performance, reduce installation complexity, and enhance the reliability of your control systems. Contact VIOX today to discover how the FCT18-Ata can optimize your timing control applications and elevate your operational efficiency.