ASTP-Y цагийн реле
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Шаардлагаа илгээнэ үү, бид танд 12 цагийн дотор үнийн санал өгөх болно
- УТАС:+8618066396588
- Whatsapp:+8618066396588
- Имэйл:sales@viox.com
VIOX ASTP-Y Analog Timer
Тойм
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Гол онцлогууд
- Цагийн нарийн хяналт: Аналог залгах үед 0-ээс 60 секундын хооронд тохируулах боломжтой.
- Найдвартай ажиллагаа: Тогтоосон хугацааны дараа релений контактуудыг сольж, байрлалаа хадгална.
- Хос релений гаралт: Тус бүр нь 5А-ийн хамгийн их ачаалалтай хоёр реле гаралт.
- Хялбар суурилуулалт: DIN төмөр замд суурилуулах PF083A суурийг багтаасан.
- Харааны үзүүлэлтүүд: Хялбар хянах зориулалттай урд самбарын ажлын үзүүлэлт.
- Удаан эдэлгээтэй барилга байгууламж: Механик болон цахилгааны ашиглалтын хугацаа өндөртэй, удаан хугацаанд ажиллах зориулалттай.
- Өргөн хүчдэлийн хүрээ: +/-10% хүлцэх чадвартай 230 VAC дээр ажилладаг.
Үзүүлэлтүүд
CLASSIFICATION | TIMER | TIMER | ||||||
ЗАГВАР | ASTP-N | ASTP-Y | AH2-N | AH2-Y | ||||
APPEARANCE | ||||||||
DIMENSIONS | 61H×49W×70D | 88H×58W×68D | 61H×49W×70D | 88H×58W×68D | ||||
MOUNTING & SOCKET |
SURFACE(-N) | PF083A(E) PS-08 | PF083A(E) PS-08 | |||||
FLUSH(-Y) | US-08 P3G-08 | US-08 P3G-08 | ||||||
FULL TIMING RANGE | SEC:1,3,6,10,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
SEC:1,3,6,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
||||||
RATED VOLTAGE | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | ||||||
INDICATOR OPERATING | Time Operating | ON-UP Two indicator Lamp ON-UP | ||||||
CONTACT | ЗАГВАР | ASTP-N1/ ASTP-Y1 | ASTP-N2/ ASTP-Y2 | ASTP-N/ ASTP-Y | AH2-N1/ AH2-Y1 | AH2-N2/ AH2-Y2 | AH2-N/ AH2-Y | |
TIME LIMIT 1C | 5А | 5А | 5А | 5А | ||||
TIME LIMIT 2C | 5А | 5А | ||||||
INSTANTANEOUS 1C | 5А | 5А | ||||||
LIFE | MECHANICAL | 5×106 удаа | 5×106 удаа | |||||
ELECTRICAL | 105 удаа | 105 удаа | ||||||
ACCURACY | REPEAT ERROR | ±1% max | ±1% max | |||||
SETTING ERROR | ±10% max | ±10% max | ||||||
VOLTAGE ERROR | ±1% max | ±1% max | ||||||
TEMP. ERROR | ±2% max | ±2% max | ||||||
RESET TIME | 0.1 sec max | 0.1 sec max | ||||||
CONSUMED POWER | 2VA | 3VA | ||||||
AMBIENT TEMPERATURE | -10℃~+55℃ | -10℃~+55℃ | ||||||
AMBIENT HUMIDITY | 48~85%RH | 48~85%RH | ||||||
WEIGHT | 220 гр | 220 гр | ||||||
CONNECTION DIAGRAMS & TIMING CHART | 39A | 39B | 39C | 39D | 39E | 39F |
Хэрэглээ
VIOX ASTP-Y аналог таймер нь үйлдвэрлэлийн автоматжуулалт болон механик төхөөрөмжүүдийн төрөл бүрийн хэрэглээнд тохиромжтой. Энэ нь хяналтын самбар, машин механизм болон цаг хугацааны нарийн хяналт шаарддаг бусад системд ашиглахад тохиромжтой. Таймерын бат бөх дизайн, найдвартай ажиллагаа нь түүнийг арилжааны болон үйлдвэрлэлийн орчинд ашиглахад маш сайн сонголт болгодог.
Техникийн өгөгдөл
- Эрчим хүчний хангамж: 230 VAC +/-10%
- Гаралт: Реле
- Макс. Ачаалах: 5А
- Цагийн хүрээ: 0-60 секунд
- Хэмжээ: 40×50 mm
- Ассемблей: DIN төмөр зам, Хүснэгтэнд
- Шийдвэр: Аналог залгах
- Хамгаалалтын зэрэг: IP 40
- Механик амьдрал: 5×106 удаа
- Цахилгаан ашиглалтын хугацаа: 105 удаа
- Нарийвчлал: Давталтын алдаа: ±1% Макс., Тохиргооны алдаа: ±10% Макс., Хүчдэлийн алдаа: ±1% Макс., Темп. Алдаа: ±2% Макс.
- Цагийг дахин тохируулах: 0.1 сек. Макс.
- Хэрэглэсэн эрчим хүч: 2VA
- Орчны температур: -10 хэмээс +55 хэм хүртэл
- Орчны чийгшил: 48%-аас 85% RH хүртэл
- Жин: 220 гр
Холболтын диаграм
VIOX ASTP-Y аналог таймер нь суулгахад хялбар энгийн холболтын диаграммтай. Төхөөрөмж нь тэжээлийн хүчдэлийг залгах үед тогтоосон хугацааг тоолж эхэлдэг бөгөөд дараа нь релений контактуудыг сольж, энэ байрлалд хэвээр үлдэнэ. А1 реле нь самбар дээрх тогтоосон цагийн дагуу ажилладаг бол А2 реле нь таймерын тэжээлийн хангамжийн дагуу ажилладаг.