ASTP-Y цагийн реле
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Шаардлагаа илгээнэ үү, бид танд 12 цагийн дотор үнийн санал өгөх болно
- УТАС:+8618066396588
- Whatsapp:+8618066396588
- Имэйл:sales@viox.com
VIOX ASTP-Y Analog Timer
Тойм
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Гол онцлогууд
- Precise Timing Control: Adjustable time range from 0 to 60 seconds with an analog dial.
- Reliable Operation: Switches relay contacts after the set time and maintains the position.
- Dual Relay Outputs: Two relay outputs with a maximum load of 5A each.
- Хялбар суурилуулалт: Includes PF083A base for DIN rail mounting.
- Visual Indicators: Front panel work indicator for easy monitoring.
- Удаан эдэлгээтэй барилга байгууламж: Designed for long-lasting performance with high mechanical and electrical life.
- Өргөн хүчдэлийн хүрээ: Operates on 230 VAC with a tolerance of +/-10%.
Үзүүлэлтүүд
CLASSIFICATION | TIMER | TIMER | ||||||
ЗАГВАР | ASTP-N | ASTP-Y | AH2-N | AH2-Y | ||||
APPEARANCE | ||||||||
DIMENSIONS | 61H×49W×70D | 88H×58W×68D | 61H×49W×70D | 88H×58W×68D | ||||
MOUNTING & SOCKET |
SURFACE(-N) | PF083A(E) PS-08 | PF083A(E) PS-08 | |||||
FLUSH(-Y) | US-08 P3G-08 | US-08 P3G-08 | ||||||
FULL TIMING RANGE | SEC:1,3,6,10,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
SEC:1,3,6,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
||||||
RATED VOLTAGE | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | ||||||
INDICATOR OPERATING | Time Operating | ON-UP Two indicator Lamp ON-UP | ||||||
CONTACT | ЗАГВАР | ASTP-N1/ ASTP-Y1 | ASTP-N2/ ASTP-Y2 | ASTP-N/ ASTP-Y | AH2-N1/ AH2-Y1 | AH2-N2/ AH2-Y2 | AH2-N/ AH2-Y | |
TIME LIMIT 1C | 5A | 5A | 5A | 5A | ||||
TIME LIMIT 2C | 5A | 5A | ||||||
INSTANTANEOUS 1C | 5A | 5A | ||||||
LIFE | MECHANICAL | 5×106 times | 5×106 times | |||||
ELECTRICAL | 105 times | 105 times | ||||||
ACCURACY | REPEAT ERROR | ±1% max | ±1% max | |||||
SETTING ERROR | ±10% max | ±10% max | ||||||
VOLTAGE ERROR | ±1% max | ±1% max | ||||||
TEMP. ERROR | ±2% max | ±2% max | ||||||
RESET TIME | 0.1 sec max | 0.1 sec max | ||||||
CONSUMED POWER | 2VA | 3VA | ||||||
AMBIENT TEMPERATURE | -10℃~+55℃ | -10℃~+55℃ | ||||||
AMBIENT HUMIDITY | 48~85%RH | 48~85%RH | ||||||
WEIGHT | 220g | 220g | ||||||
CONNECTION DIAGRAMS & TIMING CHART | 39A | 39B | 39C | 39D | 39E | 39F |
Хэрэглээ
The VIOX ASTP-Y Analog Timer is ideal for a variety of applications in industrial automation and mechanical devices. It is suitable for use in control panels, machinery, and other systems requiring precise timing control. The timer’s robust design and reliable performance make it an excellent choice for both commercial and industrial environments.
Техникийн өгөгдөл
- Power Supply: 230 VAC +/-10%
- Output: Реле
- Max. Load: 5A
- Time Range: 0-60 seconds
- Хэмжээ: 40×50 mm
- Assembly: DIN Rail, In the table
- Шийдвэр: Analog Dial
- Degree of Protection: IP 40
- Mechanical Life: 5×106 times
- Electrical Life: 105 times
- Accuracy: Repeat Error: ±1% Max., Setting Error: ±10% Max., Voltage Error: ±1% Max., Temp. Error: ±2% Max.
- Reset Time: 0.1 Sec. Max.
- Consumed Power: 2VA
- Ambient Temperature: -10℃ to +55℃
- Ambient Humidity: 48% to 85% RH
- Жин: 220g
Холболтын диаграм
The VIOX ASTP-Y Analog Timer features a straightforward connection diagram for easy installation. The device starts counting the set time when the power supply voltage is applied, then switches the relay contacts and remains in this position. Relay A1 operates according to the set time on the panel, while Relay A2 operates according to the timer power supply.
Output Modes
When the power supply voltage is applied, the device starts counting the set time and then switches the relay contacts, maintaining this position. Relay A1 works according to the set time on the panel, and Relay A2 works according to the timer power supply. Below is the operation diagram: