VIOX VRC1-125-B 100A 2P RCCB
VIOX VRC1-125-B RCCB offers superior protection against earth faults and electric leakage for systems up to 100A. This IEC61008-1 and IEC62423 compliant device features a 10kA rated limited short circuit current and supports residual operation currents of 0.03A, 0.1A, and 0.3A. Available in 2P configuration, it operates at 240/415V AC, 50/60Hz. Key advantages include Type B characteristics, IP20 protection, and a 4,000-cycle mechanical life. With its ergonomic design, contact position indication, and finger-protection terminals, this RCCB ensures easy operation and enhanced safety. Suitable for residential, commercial, and industrial applications, it offers automatic circuit cut-off and high short circuit tolerance. The device’s flame-resistant and impact-resistant construction, coupled with its 25mm² terminal capacity and 35.5mm DIN rail mounting, makes it ideal for various earth leakage protection needs in distribution boards and electrical circuits.
Atsiųskite savo reikalavimus, mes pateiksime jums pasiūlymą per 12 valandų
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
VIOX VRC1-125-B 100A 2P RCCB liekamosios srovės grandinės pertraukiklis
Apžvalga
The VIOX VRC1-125-B is a high-performance Residual Current Circuit Breaker (RCCB) designed for superior protection against earth faults and electric leakage. With its advanced features and reliable performance, this RCCB ensures enhanced safety in various electrical installations.
Pagrindinės funkcijos
- Ergonomic cambered cover and handle for comfortable operation
- Contact position indication window for easy status checking
- Transparent clamshell with label for clear identification
- Quick fault identification with handle tripping to middle position
- Earth fault, electric leakage, and isolation protection functions
- High short circuit current tolerance
- Finger-protection wiring terminal for added safety
- High flame-resisting, temperature-resisting, and impact-resisting engineering plastic construction
- Automatic circuit cut-off when earth fault or electric leakage exceeds stipulated value
- Independent dynamic and wire pressure, unaffected by external disturbances and voltage fluctuations
Techninės specifikacijos
- Standard: IEC61008-1, IEC62423
- Type: Electronic type (Auxiliary Electromagnetic type)
- Characteristics of residual operation current: Type B
- Poles: 2P (1P+N, 3P+N available)
- Rated operating break capability: 10 InA
- Rated current: 100A (25A, 40A, 63A also available)
- Rated voltage: AC 240/415V
- Rated frequency: 50/60 Hz
- Rated residual operation current (I△n): 0.03A, 0.1A, 0.3A
- Rated residual non-operating current: 0.5I△n
- Rated limited short circuit current: 10 kA
- Rated limited residual short circuit current: 10 kA
- Scope of residual operating current: 0.5I△n~I△n
- Mechanical electrical life: 4,000 cycles
- Wiring section area of terminal: conductor of 25 mm² and below
- Installation: 35.5mm guide rail / Vertical installation
- Enclosure protection class: IP20
Basic Parameters
Nominali srovė of housing grade Inm(A) |
Stulpai | Dažnis (Hz) |
Rated voltage Ue(V) |
Nominali srovė Į (A) |
Rated residual current(A) |
Rated limited trumpasis jungimas current Inc(A) |
Rated limited residual short circuit current I△C(A) |
63 | 1P+N | 50/60 Hz | 240 | 25 40 63 | 0.03 0.1 0.3 | 10000 | 10000 |
3P+N | 415 |
Standard value of breaking time and non-operating time for pulse DC residual current and smooth DC residual current produced by rectifying circuit
Tipas | Į (A) | I△n(A) | Standard value of breaking time and non-operating time for equality of residual current (I△A ) and following values (S) |
|||
2 I△n | 4 I△n | 10 I△n | 5A,10A,20A,50A,100A,200A | |||
General type | Any value | Any value | 0.3 | 0.15 | 0.04 | 0.04 |
Range of tripping current(Table 1)
Modelis | Tripping current I△ /A | ||
AC | 0.5 I△n<I△n | ||
A | Angle of retard | I△n>0.01A | I△n<0.01A |
0° | 0.35I△n≤I△≤1.4I△n | 0.35I△n≤I△≤2I△n | |
90° | 0.25I△n≤I△≤1.4I△n | 0.25I△n≤I△≤2I△n | |
135° | 0.1I△n≤I△≤1.4I△n | 0.1I△n≤I△≤2I△n |
Different from (B type) of 50/60 Hz as per frequency(Table 2)
Frequency(Hz) | Residual non-operating current | Residual operating current |
150 | 0.5I△n | 2.4I△n |
400 | 0.5I△n | 6I△n |
1000 | I△n | 14I△n |
Paraiškos
- Gyvenamųjų namų elektros sistemos
- Komerciniai pastatai
- Industrial installations
- Paskirstymo skydai
- Earth leakage protection in various electrical circuits
Privalumai
- Enhanced safety with multiple protection functions
- High short circuit current tolerance for improved reliability
- Lengvas montavimas ir priežiūra
- Clear status indication for quick fault identification
- Patvari konstrukcija užtikrina ilgalaikį veikimą
- Atitinka tarptautinius kokybės užtikrinimo standartus
Saugos funkcijos
- Earth fault protection
- Electric leakage protection
- Isolation protection
- Finger-protection wiring terminal
- Automatic circuit cut-off for faults exceeding stipulated values
Kokybės užtikrinimas
VIOX is committed to providing high-quality RCCBs that meet international standards. Our products undergo rigorous testing to ensure reliability, safety, and long-term performance in various electrical installations.
Įrengimas
The VIOX VRC1-125-B RCCB is designed for easy installation on 35.5mm guide rails or vertical mounting. Its compact design and clear labeling facilitate quick and efficient installation in distribution boards and electrical panels.