VIOX VL16-40 AC tipo 1P+N RCBO

VIOX VL16-40 AC Type 1P+N RCBO offers comprehensive protection for household and commercial distribution systems. This IEC/EN61009-1 compliant device safeguards against earth faults, short-circuits, and overloads with a 10kA rated short-circuit capacity. Available in 1A to 40A ratings, it operates at 240V AC, 50/60Hz, with residual current options of 30mA, 100mA, or 300mA. Featuring B, C, or D tripping curves and instantaneous tripping ≤0.1s, it provides efficient protection against insulation failures and direct human contact. With easy DIN rail mounting and 4000 cycle electro-mechanical endurance, this versatile RCBO ensures reliable electrical safety for various applications.

Atsiųskite savo reikalavimus, mes pateiksime jums pasiūlymą per 12 valandų

VIOX VL16-40 AC Type 1P+N Residual Current Circuit Breaker with Overcurrent Protection RCBO

Apžvalga

The VIOX VL16-40 RCBO provides comprehensive protection for household and commercial distribution systems. It offers protection against earth fault/leakage current, short-circuit, overload, and functions as an isolation device. This device effectively safeguards electric equipment against insulating failure and provides complementary protection against direct contact by human body.

Pagrindinės funkcijos

  • Standards: IEC/EN61009-1
  • Type: Electro-magnetic type
  • Residual current characteristics: AC A
  • Pole No.: 1P+N
  • Suklupimo kreivė: B, C, D
  • Rated short-circuit capacity: 10kA
  • Rated current (A): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A
  • Rated voltage: 240V AC
  • Nominalusis dažnis: 50/60 Hz
  • Rated residual operating current(mA): 0.03, 0.1, 0.3
  • Tripping duration: instantaneous≤0.1s
  • Elektromechaninė ištvermė: 4000 ciklų

Techninės specifikacijos

  • Connection terminal: pillar terminal with clamp
  • Connection capacity: Rigid conductor 16mm²
  • Terminal connection height: 21.5mm
  • Installation: On symmetrical DIN rail 35mm or Panel mounting

Apsaugos nuo perkrovos srovės charakteristikos

Bandymo procedūra Tipas Bandomoji srovė Pradinė būsena Kelionės arba ne kelionės laiko limitas Laukiamas rezultatas Pastaba
a B, C, D 1.13In šaltas t≥1h No tripping
b 1.45In po bandymo a t<1h suklupimas Current in the 5s in the increase of stability
c 2.55In šaltas 1s<t<60s suklupimas
d B
C
D
3In
5In
10In
šaltas t≥0,1s No tripping Įjunkite pagalbinį jungiklį, kad uždarytumėte srovę
e B
C
D
5In
10In
20In
šaltas t<0,1s suklupimas Įjunkite pagalbinį jungiklį, kad uždarytumėte srovę

The terminology “cold state” refers to that no load is carried before testing at the reference setting temperature.

Residual Current Action Breaking Time

Tipas Į/A I△n/A Likutinė srovė (I△) atitinka tokį lūžio laiką (S)
AC type any value any value Į 2In 5In 5A,10A,20A,50A,100A,200A,500A
A type any value >0.01 1.4In 2.8In 7In
0.3 0.15 0.04 0.04 Maksimalus pertraukos laikas
Bendrojo tipo RCBO, kurio srovė IΔn yra 0,03 mA arba mažesnė, vietoj 5IΔn gali naudoti 0,25 A.

Charakteristinė kreivė

Elektros instaliacijos schema