VIOX CTB2260 Ceramic Terminal Block offers a 2-in-2-out, 60A design for high-current demands. With heat resistance up to 750°C, it’s perfect for heavy industrial machinery and power distribution. Trust VIOX for secure, reliable connections in extreme high-temperature industrial settings.
Saatke oma nõuded, me teeme teile hinnapakkumise 12 tunni jooksul.
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
The CTB2260 Ceramic Terminal Block represents the pinnacle of high-amperage electrical connection technology, designed specifically for the most demanding industrial applications requiring substantial current capacity. This premium 2-in-2-out terminal block delivers exceptional performance with its 60A current rating, combining superior thermal stability with unmatched electrical insulation properties that make it the definitive choice for critical power distribution applications where standard terminal blocks simply cannot perform.
Industrial-Strength Design for Maximum Power Applications
The CTB2260 features a heavy-duty 2-in-2-out configuration engineered specifically to handle substantial current loads up to 60A while maintaining temperature stability and connection integrity. Precision-crafted from high-frequency ceramic material, this terminal block delivers superior insulation properties and heat resistance that far surpass conventional alternatives, making it indispensable for high-current, high-temperature environments where plastic or phenolic terminal blocks would rapidly degrade or fail entirely.
Each CTB2260 incorporates extra-large connection points with substantial copper core conductors specifically designed for optimal electrical performance under extreme current loads. The M6-compatible screw terminals, manufactured from robust iron-plated zinc material, provide exceptional clamping force for secure connections with the heavier gauge wires required in high-amperage applications – maintaining reliable contact under conditions that would cause standard terminal blocks to overheat or lose connection integrity.
Key Features and Technical Advantages
- Exceptional Current Handling: 60A rating delivers substantial capacity for heavy industrial power applications requiring significant current flow
- Expanded Wire Capacity: Accommodates wire gauges from 2.5mm² to 16mm², supporting the large conductors essential for high-amperage installations
- Oversized Wire Entry: 6mm diameter wire entry holes facilitate smooth installation of heavy gauge wires
- Dual Circuit Configuration: Two-in, two-out design enables complex power distribution configurations in industrial settings
- M6 Screw Compatibility: Heavy-duty screw size provides superior clamping force for maintaining secure connections under high-current conditions
- Extraordinary Temperature Resistance: Withstands continuous operation at temperatures up to 750°C without degradation
- Suurepärane elektriisolatsioon: Ceramic material provides exceptional dielectric strength, preventing current leakage even at elevated temperatures and voltages
- Enhanced Dimensional Stability: Larger overall dimensions (38.7mm × 31mm × 22.7mm) provide improved mechanical stability and heat dissipation
- Flame Retardant: Naturally fire-resistant ceramic material eliminates ignition risk in critical power installations
- Chemical Resistance: Impervious to oils, solvents, and corrosive industrial chemicals
Tehnilised andmed
SPECIFICATION | MUDEL | LENGTH | WIDTH | HEIGHT | WIRING RANGE |
---|---|---|---|---|---|
1 In 1 Out 10A | CTB1110 | 19mm | 10mm | 15mm | 0.5-2.5mm2 |
1 In 1 Out 30A | CTB1130 | 18mm | 14mm | 18mm | 0.5-6mm2 |
2 In 2 Out 10A | CTB2210 | 20.7mm | 18.9mm | 13.9mm | 0.5-2.5mm2 |
2 In 2 Out 15A | CTB2215 | 28.4mm | 20.4mm | 16.3mm | 0.5-4mm2 |
2 In 2 Out 30A | CTB2230 | 31mm | 27mm | 18.9mm | 1.5-6mm2 |
2 In 2 Out 60A | CTB2260 | 38.7mm | 31mm | 22.7mm | 2.5-16mm2 |
2 In 2 Out 100A | CTB22100 | 41.1mm | 30.2mm | 25.85mm | 6-25mm2 |
3 In 3 Out 10A | CTB3310 | 31mm | 20mm | 14.3mm | 0.5-2.5mm2 |
3 In 3 Out 15A | CTB3315 | 35.5mm | 20.3mm | 20.2mm | 0.5-4mm2 |
3 In 3 Out 30A | CTB3330 | 46.2mm | 26.4mm | 19.2mm | 1.5-6mm2 |
4 In 4 Out 30A | CTB4430 | 57mm | 25mm | 18.8mm | 1.5-6mm2 |
5 In 5 Out 15A | CTB5515 | 50mm | 22mm | 13mm | 0.5-2.5mm2 |
6 In 6 Out 15A | CTB6615 | 56.6mm | 21mm | 13mm | 0.5-2.5mm2 |
8 In 8 Out 15A | CTB8815 | 68mm | 21mm | 13mm | 0.5-2.5mm2 |
10 In 10 Out 15A | CTB101015 | 88mm | 18mm | 15mm | 0.5-3.5mm2 |
CTB2260 Detailed Specifications:
- Praegune hinnang: 60A
- Configuration: Two-in, Two-out
- Mõõtmed: 38.7mm (L) × 31mm (W) × 22.7mm (H)
- Wire Range: 2.5-16mm²
- Wire Entry Hole Diameter: 6mm
- Korpuse materjal: High-frequency ceramic
- Conductor Material: Heavy-duty copper core
- Screw Material: Iron-plated zinc
- Screw Compatibility: M6 thread
- Compatible Wire Types: Suitable for both soft and hard wires
- Maximum Operating Temperature: 750°C
- Dielektriline tugevus: 4kV
- Isolatsioonikindlus: >2000MΩ at 500VDC
- Contact Resistance: <0.15mΩ
- Maximum Torque: 2.5-3.0 N·m
- Pingeklass: 750V AC/DC
Critical Heavy-Industry Applications
The CTB2260 Ceramic Terminal Block is specifically engineered for specialized industrial applications where high current capacity, extreme temperature conditions, and absolute reliability are non-negotiable requirements:
- Heavy Industrial Machinery: Power connections for large industrial motors, heavy-duty pumps, and industrial compressors
- Metal Processing Equipment: Power distribution in foundries, steel mills, and metal fabrication facilities
- Tööstuslik elektrijaotus: Main feed connections in distribution panels and industrial power centers
- High-Temperature Industrial Processing: Industrial furnaces, smelting operations, and glass manufacturing
- Industrial Heating Systems: High-power heating elements, industrial boilers, and specialized heating applications
- Heavy-Duty Welding Equipment: Primary power connections for industrial welding systems
- Transportation Infrastructure: Power distribution in railway systems, shipyards, and heavy vehicle manufacturing
- Power Generation Equipment: Connection points in generators, power conversion systems, and distribution infrastructure
- Mining Operations: Electrical systems for mining machinery and processing equipment
Professional Installation Guidelines
For optimal performance, safety compliance, and long-term reliability in high-current applications, follow these specialized installation guidelines:
- Ensure the mounting surface is robust, heat-resistant, and provides adequate space for heat dissipation
- Strip wires to the appropriate length (typically 12-15mm for larger gauge conductors)
- For stranded conductors, use ferrules or tinning to ensure optimal connection integrity
- Fully loosen terminal screws before inserting wires to prevent conductor damage
- Insert wire completely into the terminal opening, ensuring no exposed conductor extends beyond the ceramic housing
- Tighten M6 screws progressively to a final torque of 2.5-3.0 N·m
- Verify connection integrity through both visual inspection and a mechanical pull test
- Implement a regular maintenance schedule for inspection and re-torquing of high-current connections
- Maintain minimum clearance of 15mm between adjacent high-current terminal blocks
- For currents approaching the 60A rating, consider implementing additional heat dissipation measures
The CTB2260 Advantage: Engineering Excellence for Critical Power Applications
For electrical systems where standard terminal blocks would be pushed beyond their limits, the CTB2260 Ceramic Terminal Block represents the definitive solution. Its combination of exceptional current capacity, superior temperature resistance, and unmatched electrical insulation properties makes it indispensable for critical industrial applications where connection failure is simply not an option.
Trust in the proven performance of our advanced ceramic terminal block technology combined with precision engineering to provide safe, reliable electrical connections for your most demanding high-current applications. The CTB2260 embodies the perfect balance of current-carrying capacity, thermal performance, and long-term reliability for today’s most challenging industrial electrical environments.